3
INSTALLATION
Service Connections
DIMENSIONS
A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
Q
FT-6
12
[305]
14.5
[368]
19.5
[495]
349
[349]
5
[127]
7.5
[191]
15.12
[384]
8.5
[216]
12.25
[311]
10.38
[264]
30.25
[768]
4
[102]
4.38
[111]
34.12
[867]
0 [0]
16
[406]
FT-10
16
[406]
15
[381]
18.5
[470]
13.75
[349]
7
[178]
7.75
[197]
19.12
[486]
9
[229]
13.25
[413]
8.88
[225]
32.25
[819]
2.38
[60]
4.88
[124]
33.12
[841]
0 [0] 19.25
[489]
FT-12
16
[406]
17
[432]
20.5
[521]
13.75
[349]
7
[178]
7.75
[197]
19.12
[486]
9
[229]
16.25
[413]
10.88
[276]
39.5
[1003]
2.38
[60]
4.88
[124]
35.12
[892]
0 [0] 19.25
[489]
FT-20
21
[533]
18
[457]
26.5
[673]
23.5
[597]
1.5
[38]
6.25
[159]
24.12
[613]
15.25
[387]
15.75
[400]
10.5
[267]
40.5
[1029]
7.5
[191]
11.12
[283]
42.38
[1076]
1.5
[38]
26
[660]
G
Q
E
FT-6
FT-10 & FT-12
G
E
Q
FT-20
G
E
Q
B
ØA
D
CR
S
M
N
H
C
O
POUR PATH
F
P
K
J MIN.
L
SERVICE CONNECTIONS
S Steam Supply - 1/2” (13mm) IPS, 15-50 PSI (1.0-3.5
kg/cm2). Pressure reducing valve is required if incoming
pressure exceeds 50 PSI (3.5 kg/cm2)
CR Condensate Return - 1/2” (13mm) IPS.
Installation Clearance: When installing kettles against combus-
tible/non-combustible surfaces (rear walls) 1” (25mm) minimum
clearance is required and (side walls) 3” (76mm) minimum clear-
ance is required.
Figure 1