SEPTEMBER 16, 2014
8
F-PEF & F-LEF STATIONARY ELECTRIC KETTLES
MATERIAL SAFETY DATA SHEET
Product: DOWFROST
TM
HD HEAT TRANSFER FLUID, DYED
Product Code: 04632
Effective Date: 02/20/01 Date Printed: 07/10/02, MSD: 002239
HAZARDOUS COMBUSTION PRODUCTS:
During a fire, smoke may contain the original material in addition to unidenti
-
fied toxic and/or irritating compounds. Hazardous combustion products may include and are not limited to carbon monoxide
and carbon dioxide.
OTHER FLAMMABILITY INFORMATION:
Violent steam generation or eruption may occur upon application of direct water
stream to hot liquids. Flammable concentrations of vapour can accumulate at temperatures above 214°F. Liquid mist of this
product can burn. Spills of these organic liquids on hot fibrous insulations may lead to lowering of the autoignition tempera
-
tures possibly resulting in spontaneous combustion. Container may rupture from gas generation in a fire situation.
EXTINGUISHING MEDIA:
Water fog or fine spray, carbon dioxide, dry chemical, foam. Alcohol resistant foams (ATC type)
are preferred if available. General purpose synthetic foams (including AFFF) or protein foams may function, but much less
effectively. Do not use direct water stream. May spread fire.
MEDIA TO BE AVOIDED:
Do not use direct water stream.
FIRE FIGHTING INSTRUCTIONS:
Keep people away. Isolate fire area and deny unnecessary entry. Burning liquids may
be moved by flushing with water to protect personnel and minimize property damage. Burning liquids may be extinguished
by dilution with water. Do not use direct water stream. May spread fire. Fight fire from protected location or safe distance.
Consider use of unmanned hose holder or monitor nozzles. Use water spray to cool fire exposed containers and fire af
-
fected zone until fire is out and danger of re-ignition has passed. Immediately withdraw all personnel from area in case of
rising sound from venting safety device or discolouration of the container. Move container from fire area if this is possible
without hazard.
PROTECTIVE EQUIPMENT FOR FIRE FIGHTERS:
Wear positive-pressure self-contained breathing apparatus (SCBA)
and protective fire fighting clothing (includes fire fighting helmet, coat, pants, boots and gloves). If protective equipment is
not available or not used, fight fire from a protected location or safe distance.