background image

EN standard

Diameter and 

length of rope

Date of production, 

Manufacturer

2.2 Marking

This product has a serial number engraved in the housing. You will also find the serial on 
the first page of these instructions for use.

  1 CE marking of the supervisory authority
  2 Perform an inspection regularly / at least once a year
  3 Max. Number of people with simultaneous use
 4  Max. Descent height acc. standard (multiple use)
 5  Serialnumber
 6 Production year and months
 7  Product name 
 8  Manufacturer 
 9 Always read and follow the instructions for use!
10 Warning: hot surface
11  Avoid descending into electrical, thermal, chemical or other hazardous areas 
12 Application temperature range
13 Max. and min. rated load 
14 Compatible rope sizes and types
15 Harmonized standards

5

15

12
13

3

11

7

6

8

1

9

14

2

4

10

 9

 EN1891A:1998 - 10,5mm - L: 10m

 MM/JJ: 11/20 - MARK Save A Life

Rope marking

Содержание Allstar

Страница 1: ...ave A Life GmbH Gleinkerau 23 4582 Spital am Pyhrn sterreich Europa Tel 43 7563 8002 111 Fax 43 7563 8041 111 mark savealife at www savealife at www facebook com makingyourlifesafer Serial number Desc...

Страница 2: ...DATA SHEET...

Страница 3: ...manual including the inspection protocol must be kept with the product In case of loss or if manual and inspection protocol became unusable the effective versions of both documents are available for d...

Страница 4: ...falls from a height long rope end avoid slack rope short rope end In order to make our texts easier to read we dispense with gender differentiation and write main personal words in the male form This...

Страница 5: ...11 2 7 Rescue deployment 11 2 8 Overload 11 2 9Temperature 11 3 USE 12 3 1 Intended use 12 3 2 Important notes on the usage of the eyebolts 13 3 3 Abseiling with MARK Allstar 14 3 4 No move during li...

Страница 6: ...10 LEGAL INFORMATION 24 10 1 Declaration of conformity 24 10 2 Product liability 24 10 3 Copyright 24 10 4 Trademarks 24 11 DECLARATION OF CONFORMITY 25 12 TEST PROTOCOL 26 13 USAGE OVERVIEW 28 4...

Страница 7: ...owing categories are being used DANGER WARNING CAUTION and NOTE Follow the safety instructions to avoid personal injuries or damage of the product DANGER means that death or a serious injury are very...

Страница 8: ...safe anymore e g rope damaged etc send it to MARK Save A Life or an authorized partner for inspection and repair Do not use it Fill in the inspection protocol carefully Each inspection must be entered...

Страница 9: ...dried in the sun or over a heat source e g radiator Air dry this product in an airy shaded place This product the rope in particular must not be disinfected or impregnated Do not use chemicals when c...

Страница 10: ...mantleropel 9 6mm till 11mm EN 1891 A Descent lifting load max 285kg min 30kg EN 3 persons ANSI 2 persons Descent lifting height max 500 m Descent speed approx 1 0 m s with 85kg and approx 1 5 m s wit...

Страница 11: ...of people with simultaneous use 4 Max Descent height acc standard multiple use 5 Serialnumber 6 Production year and months 7 Product name 8 Manufacturer 9 Always read and follow the instructions for...

Страница 12: ...r Carabiner Anchor device Full body harness Lanyards Workpositioning The above products are featured on www savealife at If you need more information please send us an email or call us 2 5 Maximum des...

Страница 13: ...se We recommend using different devices for training and rescue deployments 2 8 Overload Devices that have been subjected to a fall or a heavy load must be retired Rope clamp When you activate the rop...

Страница 14: ...efore using this product In case of doubt or if you have questions please contact MARK Save A Life Inspection Using this product without having performed a visual and functional inspection can lead to...

Страница 15: ...using the descender as a shuttle system make sure that you use the eye bolts correctly Standard rule Only run the unloaded longer rope end through the eye bolts Longer and shorter rope end If you run...

Страница 16: ...he side of the unloaded rope end will add friction when you hold back the unloaded rope end This way you can reduce speed manually 2 Use of the rope clamp In both ways you can block the device after s...

Страница 17: ...after stopping by run ning the rope out of the device making a U turn to the eye bolt and back through the rope clamp as shown grab the handwheel while doing this 3 4 No move during lifting If it hap...

Страница 18: ...uctions for use for MARK Gekko and MARK Boa checklist for installation and regular inspection checklist inspection protocols installation protocol and sub structure checklist 3 6 Training The customer...

Страница 19: ...ter a max of 10 years textile parts must be replaced and metal parts must be inspected by MARK Save A Life The MARK Infini Box has to be inspec ted at least once a year but in any case before each use...

Страница 20: ...vice to MARK Save A Life or a authorized person to check and replace the rope Information on work according to EN 341 2011 1A work capacity 7 500 000 Joule work W m x g x h x n W work in Joule J m loa...

Страница 21: ...equipment sealed in special packaging NOTE 5 MAINTENANCE 5 1 Repairs Product changes Repairs adjustments or changes to this product that have not been authorized by MARK Save A Life can lead to sever...

Страница 22: ...k if nuts and bolts are fixed Check if the rope has cracks or other visual or palpable damage Check if the rope runs smoothly Pull both rope ends slowly one after the other If you feel slight resistan...

Страница 23: ...vice Inspection criteria Inspection required by user Inspection required by competent person Inspection required by MARK Save A Life or authorized partner Insepction required only by MARK Save A Life...

Страница 24: ...used anymore Retire this product in an environmentally friendly way Separate materials 8 RESALE To ensure safe and correct use this product may only be resold with the instructions for use and the ins...

Страница 25: ...body sitting up or squatting Open straps and tight clothes Monitor cardiovascular and respiratory system If the casualty has no signs of life start with CPR If the injured person is suspended but able...

Страница 26: ...by the accredited testing inspection and certification body Allgemeine Unfallversicherungsanstalt Adalbert Stifter Stra e 65 1200 Wien with the number Identification number 0511 is subject to the qua...

Страница 27: ...11 DECLARATION OF CONFORMITY 25...

Страница 28: ...tory number Inspections must be carried out at least once a year by a competent person Date Result remarks Inspector signature Product is OK continue using product Product is damaged retire product Pr...

Страница 29: ...tory number Inspections must be carried out at least once a year by a competent person Date Result remarks Inspector signature Product is OK continue using product Product is damaged retire product Pr...

Страница 30: ...Usage no Date Usage in meters Signature of user 13 USAGE OVERVIEW DOWNLOAD UNDER WWW SAVEALIFE AT 28...

Страница 31: ...Usage no Date Usage in meters Signature of user 13 USAGE OVERVIEW DOWNLOAD UNDER WWW SAVEALIFE AT 29...

Страница 32: ...Making your life safer...

Отзывы: