setuP menu

Max Vol: This setting lets you set a maximum Main output (and 
Auxiliary output, if set to “Main Var” in the Aux mode) volume 
level setting in 0.1dB increments between 40.0dB and 80.0dB. 
The factory default maximum volume is 80.0dB. 

Mute: This setting lets you set the amount of Main output (and 
Auxiliary output, if set to “Main Var” in the Aux mode) volume 
level attenuation that occurs when the Mute button is engaged, 
in 0.1dB increments between –10dB and –80.0dB. The factory 
default mute attenuation is –40dB.

Turn On: This setting lets you set a Main output (and Auxiliary 
output, if set to “Main Var” by the Aux button) volume level to 
which your N

0

52 will default every time you turn it on.

•  10.0dB  –  60.0dB:  Choose  a  turn-on  volume  level  in  0.1dB 

increments between 10.0db and 60.0db. The factory default 
setting is 40.0dB.

•  Last:  The  volume  level  setting  from  the  previous  time  the 

unit was powered down is retained. 

CautioN: Setting the turn on parameter to Last can result in 
louder-than-expected power-up volume if the N

0

52 was set to a 

high volume level setting when last powered down. 

Vol Taper: This setting lets you choose the desired taper for the 
volume control, from the following options:

Mode  1:  The  faster  you  rotate  the  volume  knob  the  more 
quickly  the  volume  will  change.  Rotating  the  knob  slowly 
slows the rate the volume changes, allowing you to make very 
precise adjustments in the listening level.

Mode 2: Similar to Mode 1, with a “faster” response curve, 
with more gain change for a similar range of knob travel.

Mode  3:  When  increasing  the  volume  the  volume  changes 
quickly through the low volume range, and then decelerates 
in  the  higher  range,  for  precision  adjustments.  When 
decreasing  the  volume  the  control  works  in  the  opposite 
fashion, changing quickly through the high volume range and 
decelerating in the lower range.

voLuMe CoNtRoL

Volume Control

Max Vol=XXX
Mute=XXX
Turn On=XXX
Vol Taper=XXX

Setup Menu

Input Setup

Power Mgmt

Volume Control

Advanced

Содержание N052

Страница 1: ...Reference Preamplifier Owner s Manual N0 52...

Страница 2: ...om Before you read this User Guide we recommend that you thoroughly read the N0 52 Quick Start Guide supplied with your N0 52 in printed form The Quick Start Guide contains all the information you wil...

Страница 3: ...lously balanced circuits preserve all input signal information passing it to the associated power amplifier without the limitations of asymmetrical designs In addition to the above mentioned inputs th...

Страница 4: ...used to feed powered subwoofers recording devices or a second zone The N0 52 represents the ultimate combination of compelling performance and almost limitless potential Its unique dual chassisstruct...

Страница 5: ...Input Ph Gain XXX 20Hz HPF XXX R Load XXX C Load XXX Ph Bal XXX Aux XXX Setup Menu Input Setup Power Mgmt Volume Control Advanced The Input Setup menu allows you to customize the following parameters...

Страница 6: ...e Offset parameter to the volume level of the Main and Auxiliary outputs SSP The SSP setting configures the selected input for complete integration with a multichannel surround sound processor See SSP...

Страница 7: ...o menu to continue listening as normal Ph Gain This setting lets you choose from two preset gain settings 40 0dB or 60dB for the Phono input The 60dB setting is useful for boosting signals from moving...

Страница 8: ...he previous time the unit was powered down is retained CAUTION Setting the Turn On parameter to Last can result in louder than expected power up volume if the N0 52 was set to a high volume level sett...

Страница 9: ...ontrol circuitry powered and ready to receive commands from either the front panel controls or the remote control This mode provides moderate power conservation Normal This mode shuts off the N0 52 s...

Страница 10: ...ng network related parameters Name N0 52_XXXXXX Displays your N0 52 s network name the X s represent the last six digits of the unit s unique MAC address This setting is informational only and does no...

Страница 11: ...e gain The signal at the Main outputs is also routed to the Aux outputs at a level that mirrors the Main output volume setting This mode is useful in configurations where Main and Aux signals and leve...

Страница 12: ...rround sound processor see illustration on next page 1 Make sure the N0 52 and all associated components are powered off and disconnected from electrical outlets 2 Connect the output connectors on the...

Страница 13: ...s R Input Link Su round Back Remote Zone Left Left Right Right Left Right Left Right Left Right Left Cen er Front Analog Audio Outputs Mic ophone Inputs 1 2 R R R L L L 3 3 3 1 2 1 2 3 Y Y G Pb Pb B P...

Страница 14: ...ontroller chassis is placed inside a glass cabinet tinted glass will reduce the remote control range Make sure the remote control signal is being received at the IR receiver on the Controller s front...

Страница 15: ...u is not set to Off No connectivity via Ethernet Verify that the network cables are properly connected between the router switch or hub and the N0 52 If you have connected directly to a computer verif...

Страница 16: ...ive 3 3 5 0 7 7 10 33 50 77 100 330 47k user selectable 50pF 100pF 150pF 200pF 250pF 300pF 350pF 0 01 F user selectable Output Impedance 20 ohms balanced XLR connectors 10 ohms unbalanced RCA connecto...

Страница 17: ...on Other company and product names may be trademarks of the respective companies with which they are associated This document should not be construed as a commitment on the part of HARMAN Internationa...

Отзывы: