PRIMER ORIENTATION SENSOR INSTRUCTION MANUAL VERSION 1.1

 

3

 

 

Installation Instructions: 

 

The Primer orientation sensor installs into station # 5, the station after the primer seating station.  To 
install the sensor the Shellplate must be removed or lifted to remove the spacer housing.  Although 

it’s

 

not required, we do recommend to remove the tool head for full access. Below are the installation steps 
for installing the sensor on a Revolution (shown).  Evolution and Apex10 process is the same. 

Step 1: Removing Press Top End  

1.

 

Remove Tool Head 

2.

 

Remove Shellplate nut 

3.

 

Loosen the Shellplate retainer clamps and remove the Shellplate spring. 

4.

 

Remove the Shellplate 

5.

 

Remove Spacer Block by loosening 2X 10-32 from the underside of the Priming Assembly with a 

9/64” Allen Key

 

 

Figure 1: Revolution Press Top End disassembled for Sensor Installation 

 

Revolution Press  

Spacer Block 
Hardware 

 (Re-Use)   

Содержание 101-1040

Страница 1: ...040 Mark 7 Primer Orientation Sensor Evolution Revolution Apex 10 Instruction Manual V 1 1 Read this manual completely Understand all safety and operating instructions Failure to comply with the warnings and instructions may result in serious injury illness or death ...

Страница 2: ... and Automated priming Systems The sensor is packaged in a single corrugated box 6 X 6 X 1 1 4 Please check the packaging contents below before installing the sensor Bag 1 Primer Orientation Sensor Main Body QTY 1 Bag 2 Hardware 1 Probe QTY 1 2 Probe Spring QTY 1 3 Indicator Spring QTY 1 Bag 3 Spare Hardware 1 Probe Spring QTY 1 2 Indicator Spring QTY 1 3 Mounting Hardware 8 32 Thread Size 1 2 Lon...

Страница 3: ... head for full access Below are the installation steps for installing the sensor on a Revolution shown Evolution and Apex10 process is the same Step 1 Removing Press Top End 1 Remove Tool Head 2 Remove Shellplate nut 3 Loosen the Shellplate retainer clamps and remove the Shellplate spring 4 Remove the Shellplate 5 Remove Spacer Block by loosening 2X 10 32 from the underside of the Priming Assembly...

Страница 4: ...unt of red and tacky grease on the springs Once the springs are installed insert the probe retractor into the large spring Figure 2 Pace Probe Retractor and Indicator Springs in Spring Pockets as shown Figure 3 Probe Retractor Installed with Springs NOTE The probe must be installed at a slight angle in order to clear the undercut in the priming housing Probe Spring Indicator Spring Probe SEE NOTE ...

Страница 5: ... underside of the priming system to secure the sensor the priming assembly Spare screws are included if needed Figure 4 Primer Orientation Sensor Installed Once the Sensor is fully installed add a couple drops of light weight oil on the probe retractor and moving components and manually actuate the sensor to make sure it is moving smoothly Step 4 Re install the Press components 1 Install Shellplat...

Страница 6: ...tness When you Install the Primed case you will notice the indicator Pin will move up slightly With the case installed the top of the indicator pin should be FLUSH with the top of the Sensor Housing If the sensor Housing is higher or lower loosen the two socket head Screws on the back of the sensor housing and reset the height Figure 5 Setting Optical Sensor Position Step 6 Plug the Sensor into Po...

Страница 7: ...low Figure 1 Enabling Sensor The sensor checks the primer depth when initiating a single cycle or pressing Run If a case is not present in station 5 or a case has an upside down no primer or a primer set at a depth 025 off the desired primer depth a notification can appear You must clear the notification before continuing or disable the sensor The Primer Orientation sensor if set properly will als...

Страница 8: ...eshooting Refer to the knowledge base section on our website under SUPPORT for troubleshooting articles relating to setup and operation http www markvii loading com knowledgebase Please contact us for technical support Phone 1 888 462 7577 Hours 9 00am 4 30pm ET M F ...