MAREX BATTERY INDICATOR
WITH AUTOMATIC DEEP DISCHARGE PROTECTION
•
First group (HOUSE) is service group. Second group (ENGINE) is engine start
battery (in case it is twin engine installation
– starboard engine battery).
•
System is activated by default. Red diode will blink every 30s to indicate that.
Protection can be deactivated by pressing and holding “off” button for 3
seconds. When system is deactivated, red diode no longer blinks.
•
Battery protection will turn off service batteries if service (HOUSE) battery group
voltage fall below 11,5V or get above 15,0V for longer than 200 seconds.
•
Engine start batteries are not monitored and will not be shutoff, so engine would
not be damage by sudden power loss.
•
We recommend that battery protection left on always. We want to remind that
batteries drained to 20% of their capacity (11.85V) and left uncharged for longer
periods will permanently damage batteries.