Electrical 

Parameter 

Value 

Comment 

Operating Voltage 

9 to 16 Volts 

DC Voltage 

Power Consumption 

<150mA 

Average Current Drain 

Load Equivalence Number (LEN) 

NMEA 2000

®

 Spec. (1LEN = 50 mA) 

Reverse Battery Protection 

Yes 

Indefinitely 

Load Dump Protection 

Yes 

Energy Rated per SAE J1113 

 

Mechanical 

Parameter 

Value 

Comment 

Size 

4.25” Diameter x 3.45” Tall

(108mm Dia. x 88mm Tall)

Including Mounting Bracket 

Weight 

10 oz. (283 g) 

Including Mounting Bracket 

Mounting 

Pole 

Fits 1”-14 Standard Marine Mount 

 

Environmental 

Parameter 

Value 

IEC 60945 Classification 

Exposed 

Degree of Protection 

IP67 

Operating Temperature 

-25°C to 55°C 

Storage Temperature 

-40°C to 70°C 

Relative Humidity 

93%RH @40° per IEC60945-8.2 

Vibration 

2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s

2

 per IEC 60945-8.7 

Rain and Spray 

12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 

Solar Radiation 

Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 

Corrosion (Salt Mist) 

4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 

Electromagnetic Emission 

Conducted and Radiated Emission per IEC 60945-9 

Electromagnetic Immunity 

Conducted, Radiated, Supply, and ESD

 

per IEC 60945-10 

Safety Precautions 

Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12 

 
 

7  Technical Support 

If you require technical support for Maretron products, you can reach us in one of the following 
ways: 
 
 Telephone: 

1-866-550-9100 

 Fax: 

1-602-861-1777 

 E-mail: 

[email protected]

 

 

World Wide Web: 

http://www.maretron.com

 

 Mail: 

Maretron, 

LLC 

 

  Attn: Technical Support 

 

  9034 N. 23

rd

 Ave Suite 13 

 

  Phoenix, AZ 85021 USA 

Содержание WSO100

Страница 1: ...WSO100 Ultrasonic Wind Weather Station User s Manual Revision 1 2 Copyright 2012 Maretron LLP All Rights Reserved Maretron LLP 9014 N 23rd Ave 10 Phoenix AZ 85021 7850 http www maretron com Maretron...

Страница 2: ...ocking compound and cleaning agents containing acetone Updated specification tables Added more information on configuration options and transmitted messages Corrected typographical errors Updated perf...

Страница 3: ...bration 5 2 5 3 Wind Data Damping Period 5 2 5 4 Barometric Pressure Offset Calibration 5 2 5 5 Outside Humidity Offset Calibration 5 2 5 6 Outside Temperature Offset Calibration 5 2 5 7 Advanced Conf...

Страница 4: ...WSO100 User s Manual Page iv Revision 1 2 This page intentionally left blank...

Страница 5: ...Maretron WSO100 has the following features NMEA 2000 Interface Ultrasonic Wind Sensor Relative Humidity Sensor Barometric Pressure Sensor Temperature Sensor Waterproof Enclosure and Cable System 2 In...

Страница 6: ...EA 2000 cable through the standard marine pole mount and the pole mount base and connect it to the WSO100 unit see Section 2 4 below Finally attach the WSO100 to the pole mount base using the included...

Страница 7: ...ole mount base so that this hole will face forward Mounting Screw Lock Washer NMEA 2000 Cable Standard Marine Pole Mount Pole Mount Base Sensor Figure 1 Mounting the WSO100 to a Standard Marine Pole M...

Страница 8: ...by connecting the female end of the cable to the WSO100 note the key on the male connector and keyway on the female connector Be sure the cable is connected securely and that the collar on the cable c...

Страница 9: ...SO100 is not aligned exactly with the boat s centerline 2 5 3 Wind Data Damping Period You may adjust the damping that the WSO100 applies to transmitted wind speed and direction readings The WSO100 co...

Страница 10: ...rogram the NMEA 2000 device instance for the temperature transmitted in PGN 130312 You usually will not need to modify the default value of 0 unless you have multiple temperature sensors on the networ...

Страница 11: ...the Maretron DSM200 or other NMEA 2000 chartplotters or instrumentation displays with WSO100 configuration capability Please refer to your chartplotter display manual for details Users with direct ac...

Страница 12: ...ration of the Maretron WSO100 follow the troubleshooting procedures in this section to remedy simple problems Symptom Troubleshooting Procedure No data output Check the connections to the NMEA 2000 co...

Страница 13: ...Equipment Systems IEC 61162 3 Maritime Navigation and Radiocommunication Equipment Systems IEC 60945 FCC and CE Mark Electromagnetic Compatibility NMEA 2000 Parameter Group Numbers PGNs See Appendix A...

Страница 14: ...ive Humidity 93 RH 40 per IEC60945 8 2 Vibration 2 13 2Hz 1mm 13 2 100Hz 7m s2 per IEC 60945 8 7 Rain and Spray 12 5mm Nozzle 100liters min from 3m for 30min per IEC 60945 8 8 Solar Radiation Ultravio...

Страница 15: ...RETRON BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL...

Страница 16: ...WSO100 User s Manual Page 12 Revision 1 2 This Page Intentionally Left Blank...

Страница 17: ...WSO100 uses this PGN to provide a regular transmission of outside temperature relative humidity and atmospheric pressure The factory default for periodic transmission rate is twice per second The tra...

Страница 18: ...smit identical SIDs for 130306 Wind Data and 130311 Environmental Parameters to indicate that the readings are linked together i e the data from each PGN was taken at the same time although they are r...

Страница 19: ...field to a value of 0x00 to indicate that the temperature reading is a reading of atmospheric pressure 4 Pressure This field is used to indicate the atmospheric pressure in units of 0 1Pa 5 Set Humidi...

Отзывы: