Revision 1.5
Page 11
Figure 6
– TLM100 Connections
2.5.1 Connecting to NMEA 2000
®
Interface
The Maretron TLM100 provides a connection to an NMEA 2000
®
interface through a five pin
male connector (see Figure 7). You connect the TLM100 to an NMEA 2000
®
network using a
Maretron NMEA 2000
®
cable (or an NMEA 2000
®
compatible cable) by connecting the female
end of the cable to the TLM100 (note the key on the male connector and keyway on the female
connector). Be sure the cable is connected securely and that the collar on the cable connector
is tightened firmly. Connect the other end of the cable (male) to the NMEA 2000
®
network in the
same manner. The TLM100 is designed such that you can plug or unplug it from an NMEA 2000
®
network while the power to the network is connected or disconnected. Please follow
recommended practices for installing NMEA 2000
®
network products.
Figure 7
– NMEA 2000
®
Connector Face Views
3 Configuring the TLM100
The TLM100 has several configurable parameters, which are shown below including the default
values. If you are not using the default values, then you will need to refer to the corresponding
section for configuring the TLM100 appropriately.
NMEA 2000
Connector
Cable to
Sensor
Component