Maretron FFM100 Скачать руководство пользователя страница 19

 

 

 

 

 

Revision 1.2 

 

Page 15 

®

®

3.4.9  Configuring Channel #0 Temperature Label 

Program this parameter with a text string which identifies the particular temperature parameter 
being monitored by this channel.  Maretron display products will display this label text when 
you are selecting data to display. 
 

3.5  Configuring Channel #1 

3.5.1  Enabling/Disabling Channel #1 

NOTE: This parameter is available only when the Operating Mode of the FFM100 is set to 
“Two Independent Flow Rates”. 

 
By default, the channel is enabled and will measure the flow rate and transmit it over the 
NMEA 2000 network. If this parameter is programmed to “Disable”, the channel will be 
completely disabled and will not measure flow rate nor transmit it over the NMEA 2000 
network. 
 

3.5.2  Configuring Channel #1 Engine Instance 

NOTE: This parameter is available only when the Operating Mode of the FFM100 is set to 
“Two Independent Flow Rates”. 

Program this parameter to match the desired engine instance number of the flow rate and total 
fuel used for this channel. You can program this parameter to any value between 0 and 252. 
 

3.5.3  Configuring Channel #1 Engine Label 

NOTE: This parameter is available only when the Operating Mode of the FFM100 is set to 
“Two Independent Flow Rates”. 

 
Program this parameter with a text string which identifies the particular parameter being 
monitored by this channel.  Maretron display products will display this label text when you are 
selecting data to display. 

 

3.5.4  Configuring Channel #1 K-factor 

Program this parameter to match the K-factor that appears on the flow sensor connected to 
this channel. 
 

3.5.5  Configuring Channel #1 Temperature Coefficient 

NOTE: This parameter is available only when the Operating Mode of the FFM100 is set to 

Differential Mode

”. 

 
In a diesel engine, the diesel fuel is used to help cool the fuel injection system. Therefore, the 
fuel returned from the engine to the tank has a higher temperature than the fuel sent to the 
engine from the tank. Diesel fuel expands when heated. To calculate the most accurate fuel 
usage measurement, the FFM100 accounts for this expansion by sensing the temperature at 
the supply flow sensor and the receive flow sensor, and calculating the effect of the 
temperature difference on the fuel expansion. In order to do this compensation, this parameter 

Содержание FFM100

Страница 1: ...2 Page i FFM100 Fuel Flow Monitor User s Manual Revision 1 2 Copyright 2012 Maretron LLP All Rights Reserved Maretron LLP 9014 N 23rd Ave 10 Phoenix AZ 85021 http www maretron com Maretron Manual Par...

Страница 2: ...Revision History Revision Description 1 0 Release for Review 1 1 Public Release 1 2 Corrected formatting problems in certain figures Added notes about tamper proof silicone seals on sensor screws Add...

Страница 3: ...nstance 12 3 1 2 Configuring Channel 0 Installation Orientation 12 3 1 3 Configuring Channel 1 Installation Orientation 12 3 1 4 Configuring Channel 0 Allow Negative Flow 12 3 1 5 Configuring Channel...

Страница 4: ...g Channel 1 Temperature Label 16 4 Maintenance 16 5 Troubleshooting 18 6 Technical Specifications 19 7 Technical Support 20 8 Installation Template 21 9 Maretron 2 Year Limited Warranty 22 Table of Fi...

Страница 5: ...unless installed calibrated and maintained in the correct manner Please read carefully and follow these instructions for installation calibration and usage of the Maretron FFM100 in order to ensure o...

Страница 6: ...g Modes The FFM100 can operate in one of two user selectable operating modes 1 Differential Flow Rate this mode is used for diesel engines that recirculate unused fuel back into the fuel tank These en...

Страница 7: ...SP 2R E8 and M2RSP 2R E8 Accuracy and Pressure Loss Please refer to Figure 2 below for a chart detailing typical accuracy and pressure loss versus flow rate for the M4ARP 2 E8 fuel flow sensor Revisio...

Страница 8: ...the fuel tank via the return line For diesel engines the FFM100 will operate in its differential mode and will measure the net fuel consumption of these engines by separately measuring the fuel sent t...

Страница 9: ...f computing fuel consumption for a diesel engine is further complicated by the following two factors 1 Diesel fuel expands when heated 2 Diesel fuel is heated as it passes through the engine When usin...

Страница 10: ...t a diesel engine which consumes 5 28 GPH 20 LPH The fluid flow sensor you select must have sufficient range to measure the supply flow rate of the engine whose fuel consumption you are monitoring The...

Страница 11: ...Even though the fluid flow sensors used with the FFM100 are rated at 0 25 accuracy since the fuel consumption measurement is calculated as the difference of the supply and return fuel flow rates the...

Страница 12: ...Do not remove these screws Removing these screws will void the warranty on the sensor 2 Installation 2 1 Unpacking the Box When unpacking the box containing the Maretron FFM100 you should find the fol...

Страница 13: ...llation instructions that are packaged with each sensor for detailed installation instructions 2 5 Connecting the FFM100 The FFM100 requires two types of electrical connections 1 the fluid flow sensor...

Страница 14: ...uid flow sensor to channel 0 Connections to other channels are similar Fluid flow sensor FFM100 Screw Terminals Orange B lack Red Blue White Green 1 2 P0 G0 5 4 3 6 7 8 9 10 11 12 B0 C0 T0 P1 G1 A1 B1...

Страница 15: ...ance b Channel 0 Installation c Channel 1 Installation d Channel 0 Allow negative flow e Channel 1 Allow negative flow f Differential Mode Allow negative flow g Installation Description h NMEA 2000 PG...

Страница 16: ...this parameter from the factory default setting If you inadvertently install the sensor in the reverse direction rather than reinstalling the sensor you may change this parameter from Normal to Rever...

Страница 17: ...r can display this information 3 1 8 Configuring NMEA 2000 PGN Enable Disable The FFM100 is capable of transmitting NMEA 2000 messages or PGNs associated with monitored fluid senders You may individua...

Страница 18: ...nfiguring Channel 0 K factor Program this parameter to match the K factor that appears on the flow sensor connected to this channel 3 4 5 Configuring Channel 0 Data Damping Period You can configure a...

Страница 19: ...r to any value between 0 and 252 3 5 3 Configuring Channel 1 Engine Label NOTE This parameter is available only when the Operating Mode of the FFM100 is set to Two Independent Flow Rates Program this...

Страница 20: ...the total volume recorded to zero 3 5 8 Configuring Channel 1 Temperature Instance Program this parameter to match the desired instance number of the temperature reading for this channel You can progr...

Страница 21: ...to the mounting surface If the unit is loose tighten the screws holding the cable ties Check the security of the cable connected to the NMEA 2000 interface and tighten if necessary Check the security...

Страница 22: ...hecked by removing network power and measuring the resistance at an open tee between NET L and NET H signals The resistance should read approximately 60 ohms two 120 ohm terminators in parallel equals...

Страница 23: ...ame Default Rate Periodic Data PGNs 127489 Engine Parameters Dynamic 2 Times Second 127497 Trip Parameters Engine 1 Time Second 130312 Temperature 0 5 Times Second Response to Requested PGNs 126464 PG...

Страница 24: ...40 C 95 RH after 2 hour Salt Spray Per IEC 60945 8 12 Electromagnetic Emission Conducted and Radiated Emission per IEC 60945 9 Electromagnetic Immunity Conducted Radiated Supply and ESD per IEC 60945...

Страница 25: ...lease check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the dimensions Figure 9 Mounting Surface Tem...

Страница 26: ...SE WILL MARETRON BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EV...

Страница 27: ...fied in field 2 in units of 0 01 C 5 Set Temperature The FFM100 sets this field to a reserved NMEA 2000 value indicating Data Not Available 6 Reserved bits The FFM100 sets all bits in this field to a...

Страница 28: ...Trip Parameters Engine The FFM100 uses this PGN to transmit more slowly changing engine data The factory default for periodic transmission rate is once per second The transmission of this PGN can be d...

Отзывы: