CKM12 Hardware Dimensions:

Apply the CKM12 unit to control any Maretron Load Controller device such as Maretron's CLMD16 or

CLMD12 by connecting CKM12 to the same NMEA 2000® Network. The CKM12's Out of Box
Configuration allows for Toggle Operation of the first 12 Electronic Circuit Breakers on Maretron's
CLMD16 and CLMD12 Load Controller Modules. This will only occur if the CLMD16 or CLMD12 is on the
same NMEA 2000® Network as CKM12 and also has a default Out of Box Configuration. Please see the
Out of Box Configuration details in this Quick Start Guide for information on how the
CKM12's default configuration will behave when a CLMD16 or CLMD12 is on the same
network with Out of Box Configuration.

Note: Depending on desired switch control, default configuration may not work for your application and

custom configuration will be needed using Maretron N2KAnalyzer®. Applying a CLMD16 and a CLMD12
containing default Out of Box Configurations or having two CKM12 units on the same NMEA2000®

network forces the need for custom configuration.

CKM12 Application:

Not to Scale, for Reference Only

UNIT: INCH [MM]

2.30

[ 58.4 ]

6.49

[ 164.8 ]

0.55

[ 14.0 ]

4.70

[ 119.4 ]

10-32  (2 pls)

MAX TIGHTENING TORQUE 30 IN LBS.

2.35

[ 59.7 ]

1.45

[ 36.8 ]

0.75

[ 19.1 ]

0.38

[ 9.5 ]

0.75

[ 19.1 ]

6

5

4

1

2

3

NO.

DESIGNATION

1
2
3
4
5
6

BATT +

CAN L

BATT -

CAN H

CAN SHIELD

DEUTSCH PLUG DETAIL

6

5

4

1

2

3

P/N: M00313

9

9

 Rev. 1.

2

      

Page 

2

Содержание CKM12

Страница 1: ...uick Start Guide P N M003139 Rev 1 2 3 2021 Copyright 2021 Carling Technologies Inc 60 Johnson Ave Plainville CT 06062 USA All Rights Reserved https www maretron com CKM Series 12 Button Customizable...

Страница 2: ...This Page Intentionally Left Blank...

Страница 3: ...MPower CKM12 The CKM12 features 12 keys over molded with a rubberized coating The CKM12 requires only a connection to an NMEA 2000 network to begin Configure the CKM12 using Maretron N2KAnalyzer insta...

Страница 4: ...M12 s default configuration will behave when a CLMD16 or CLMD12 is on the same network with Out of Box Configuration Note Depending on desired switch control default configuration may not work for you...

Страница 5: ...CKM12 Ordering Options P N M0031399 Rev 1 2 Page 33...

Страница 6: ...ilure service required LED CAN Blue ON steady Fault ON flashing Normal operation OFF No communication LED POWER LED DIAGNOSTICS Green ON steady Normal operation ON flashing Unit exceeded 125A Max Red...

Страница 7: ...oad Module DIAG CAN A CAN B POWER 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 LED Touch Switch Green ON steady Output is activated ON flashing Overcurrent short circuit Red OFF Normal operation ON flashing...

Страница 8: ...anel Cut Out Requirement Not to Scale for Reference Only UNIT INCH MM 1 50 38 10 4 70 119 38 1 60 40 64 1 28 32 51 PANEL THICKNESS MIN 0 05 1 27 MAX 0 30 7 62 0 22 5 72 0 22 5 72 P N M0031399 Rev 1 2...

Страница 9: ...owing ways Telephone 1 866 550 9100 Fax 1 602 861 1777 E mail marine support carlingtech com World Wide Web https www maretron com Mail Carling Technologies Inc Attn Maretron Technical Support 120 Int...

Отзывы: