![Maretron A3802-1 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/maretron/a3802-1/a3802-1_user-manual_1726993015.webp)
___________________________________________________________
CKM12 User’s Manual Rev.1.1 12
Environmental Operation
Parameter
Value
Operating Temperature
-40°C to 85°C
Ingress Protection
IP69 (Front)
IP68 (Rear)
Storage Temperature
-40°C to 85°C
Ignition Protection
Ignition Protected
Environmental Testing
Parameter
Standard
Conditions
High Temperature Soak
EN 60068-2-2:2007
96hrs. @ 85°C
Low Temperature Soak
EN 60068-2-1:2007
96 hrs. @ -40°C
Temperature Cycling (Operating)
IEC 60068-2-14:2009
-40°C - 85°C (2 cycles of 8 hrs.)
Temperature Shock (Storage)
IEC 60068-2-14:2009
T
min
= -40°C, T
max
= 85°C
Simulated Solar Radiation
EN 60068-2-5:2010
(Procedure B)
10 days @ 40°C
Ignition Protection
ISO 8846
Humidity (Soak)
EN 60068-2-78:2002
RH = 93% +/-3%, Exposure 10 days
Humidity - Cyclic
EN 60068-2-30:2005
RH (> 90%), 6 cycles of 24hrs
Dust Ingress
IEC 60529:2001
Method EN60529 Section 13 Result
IP6X
Water Ingress
DIN 40050-9:1993
IEC 60529:2001
Method as DIN 40050-9 Result IP69K
Mechanical Shock - Drop Test
EN 60068-2-31:1993
500mm free-fall, all faces of 3 axes
Mechanical - Shock
60068-2-27:2009
500m/s
2
, pulse duration 11ms
Mechanical - Bump
60068-2-29:1993
400m/s
2
6ms shock pulses, 3 axes
Vibration (General)
60068-2-6: 1996
Sine shaped sweep 5 Hz to 500 Hz
Amplitude, 5g, (20 Cycles in each plane)
Vibration (Random)
EN 60068-2-64:1995
(Method 1)
Random excitation at 10, 150, 220, and
350 Hz breakpoint frequencies, 5 hours
in each axis
Vibration (Resonant Search)
60068-2-6: 1996
frequency range 10 Hz
– 2 kHz @ 5G (5
Minutes at each resonant point)
Chemical Resistance
ISO 16750-5 (Method 2)
Test method = B
Salt Spray(Corrosion Resistance)
EN 60068-2-52: 1996
Chamber Temperature = 35°C
(level 4 severity)
Component Test - Electrical
Transients Immunity
ISO 11452-2:2004
100V/m, 20MHz to
2GHz
Component Test - Electrical
Transients Emissions
ISO 13766:2006 Section 5
Annex D and Annex E
Distance of 1 m in the horizontal and
vertical polarization, 30 MHz to 1 GHz
Component Test - Electrical
Transients Conducted
ISO 7637-2:2004
Method as per ISO 7637-2-Annex
A2
Electrostatic Discharge (ESD)
ISO 10605
+/- 8 kV (Direct), +/- 15 kV (Air)