CKM12 User’s Manual Rev.1.1                                                                                                                       12 

 

Environmental Operation 

 

Parameter 

Value 

Operating Temperature 

-40°C to 85°C 

Ingress Protection 

IP69 (Front)  

IP68 (Rear) 

Storage Temperature 

-40°C to 85°C 

Ignition Protection 

Ignition Protected 

 

Environmental Testing 

 

 

Parameter 

Standard 

Conditions 

High Temperature Soak 

EN 60068-2-2:2007 

96hrs. @ 85°C 

Low Temperature Soak 

EN 60068-2-1:2007 

96 hrs. @ -40°C 

Temperature Cycling (Operating) 

IEC 60068-2-14:2009 

-40°C - 85°C (2 cycles of 8 hrs.) 

Temperature Shock (Storage) 

IEC 60068-2-14:2009 

T

min 

= -40°C, T

max 

= 85°C 

Simulated Solar Radiation 

EN 60068-2-5:2010 

(Procedure B) 

10 days @ 40°C 

Ignition Protection 

ISO 8846 

 

Humidity (Soak) 

EN 60068-2-78:2002 

RH = 93% +/-3%, Exposure 10 days

 

Humidity - Cyclic 

EN 60068-2-30:2005 

RH (> 90%), 6 cycles of 24hrs 

Dust Ingress 

IEC 60529:2001 

Method EN60529 Section 13 Result 

IP6X 

Water Ingress 

DIN 40050-9:1993 

IEC 60529:2001 

Method as DIN 40050-9 Result IP69K 

Mechanical Shock - Drop Test 

EN 60068-2-31:1993 

500mm free-fall, all faces of 3 axes 

Mechanical - Shock 

60068-2-27:2009 

500m/s

2

, pulse duration 11ms 

Mechanical - Bump 

60068-2-29:1993 

400m/s

6ms shock pulses, 3 axes 

Vibration (General) 

60068-2-6: 1996 

Sine shaped sweep 5 Hz to 500 Hz 

Amplitude, 5g, (20 Cycles in each plane) 

Vibration (Random) 

EN 60068-2-64:1995 

(Method 1) 

Random excitation at 10, 150, 220, and 
350 Hz breakpoint frequencies, 5 hours 

in each axis 

Vibration (Resonant Search) 

60068-2-6: 1996 

frequency range 10 Hz 

– 2 kHz @ 5G (5 

Minutes at each resonant point) 

Chemical Resistance 

ISO 16750-5 (Method 2) 

Test method = B 

Salt Spray(Corrosion Resistance) 

EN 60068-2-52: 1996 

Chamber Temperature = 35°C 

(level 4 severity) 

Component Test - Electrical 
Transients Immunity 

ISO 11452-2:2004 

100V/m, 20MHz to   

2GHz 

Component Test - Electrical 
Transients Emissions 

ISO 13766:2006 Section 5 

Annex D and Annex E 

Distance of 1 m in the horizontal and 

vertical polarization, 30 MHz to 1 GHz 

Component Test - Electrical 
Transients Conducted 

ISO 7637-2:2004 

Method as per ISO 7637-2-Annex 

A2 

Electrostatic Discharge (ESD) 

ISO 10605 

+/- 8 kV (Direct), +/- 15 kV (Air) 

 
 
 
 
 
 

Содержание A3802-1

Страница 1: ...___________________________________ CKM Series 12 Button Customizable Keypad User s Manual Revision 1 1 Copyright 2020 Carling Technologies Inc 60 Johnson Ave Plainville CT 06062 USA All Rights Reserv...

Страница 2: ...Cable A3703 4 ORDERING OPTIONS 4 Table 1 Ordering Options 4 INSTALLATION 5 UNPACKING THE BOX 5 CHOOSING INSTALLATION LOCATION 5 MOUNTING THE CKM12 6 Figure 6 Mounting Panel Cutout Dimension 6 CONNECTI...

Страница 3: ...e 1 Key Numbering 2 Figure 2 Hardware Description Front View 2 Figure 3 Hardware Description Side View 3 Figure 4 Hardware Description Back View 3 Figure 5 CKM to NMEA 2000 Adapter Cable A3703 4 Figur...

Страница 4: ...he NMEA2000 network to a PC running N2KAnalyzer Control MPower and other Maretron systems with the CKM12 through an NMEA 2000 Network Using standard NMEA 2000 messaging the CKM12 can illuminate any of...

Страница 5: ...as a function indicator The LEDs are located above the top row of keys and below the bottom row of keys The icons on each key are lit by an LED backlight located behind the icon LEDs can be tied to a...

Страница 6: ...CKM12 User s Manual_________________________________________ 3 CKM12 User s Manual Rev 1 1 Figure 3 Hardware Description Side View Figure 4 Hardware Description Back View...

Страница 7: ...ble with a minimum order of 100 units Contact Marine Sales carlingtech com for custom quotation Table 1 Ordering Options PART NUMBER DESCRIPTION A3802 1 CKM12 Keypad Circle on Buttons with CKM to NMEA...

Страница 8: ...NMEA 2000 Adapter Cable 2 10 32 Nuts Mounting Hardware If any of these items are missing or damaged please contact Maretron Technical Support please refer to page 13 for contact information Choosing...

Страница 9: ...to 30 In lbs Do not use permanent adhesive to install unit Certain adhesives such as methacrylate will cause cracking of the plastic enclosure The use of permanent adhesive for installation will void...

Страница 10: ...key on the male connector and keyway on the female connector Be sure the cable is connected securely and that the collar on the cable connector is tightened firmly Connect the other end of the cable b...

Страница 11: ...ance 32 The unit will pair with Maretron CLMD12 and CLMD16 to toggle each unit s first 12 ECB s ON and OFF If more than one CLMD12 CLMD16 or one of each unit is on the same NMEA 2000 network the CKM12...

Страница 12: ...as shown in Advanced Tab Key n The CKM12 has 12 Keys each with a separate indicator output number referencing each key number as depicted in Figure 1 Key Numbering on page 2 Data Instance and Indicato...

Страница 13: ...Ensure that the unit is mounted securely and cannot be moved relative to the mounting surface Check the security of the cable connected to the NMEA 2000 connector and tighten if necessary Troubleshoot...

Страница 14: ...O Acknowledge N A 059904 ISO Request N A 060928 ISO Address Claim N A 065240 ISO Address Command N A 126208 NMEA Request Command Acknowledge N A 126993 Heartbeat 1 time 60 seconds Electrical Parameter...

Страница 15: ...0 9 Result IP69K Mechanical Shock Drop Test EN 60068 2 31 1993 500mm free fall all faces of 3 axes Mechanical Shock 60068 2 27 2009 500m s2 pulse duration 11ms Mechanical Bump 60068 2 29 1993 400m s2...

Страница 16: ...n requirements below shall be limited to the repair or replacement at Carling s option of any product not meeting the above limited warranty and which is returned to Carling or if Carling is unable to...

Страница 17: ...failure to conform with such specifications samples descriptions or illustrations shall not constitute any breach of Carling s limited warranty Warranty Return Procedure To apply for warranty claims c...

Страница 18: ...eld 1 Indicator Bank Instance This field identifies the particular indicator bank to which this PGN applies Please refer to Configuring the CKM12 on page 8 for instructions on how to program the value...

Отзывы: