Mareli Systems

The main frame shows: 

time and date, chrono activation, combustion 

power and recipe, functioning state, error code, 

main temperature, main thermostat, 

summer/winter mode.

Button 

Function 

P1 

P2 

P3 

P4 

P5

 

P6

 

Exit Menu/Submenu;
Ignition and extinguishing (push for 3 seconds), Reset errors (push for 3 seconds), Enable/disable chrono;
Enter in User Menu 1/submenu, Enter in User Menu 2 (push for 3 seconds), Save data;
Enter in Visualizations Menu, Increase
Activation chrono time band
Enter in Visualizations Menu, Decrease

Led

 

Function 

D1 

D9 

D2 

D10 

D3 

D11 

D4 

D12 

Igniter ON

    Auger ON

  Pump 1 ON 

V2: 

Pump 2 ON

 

External Chrono reached

Lack of pellet

Local Room Thermostat reached

Sanitary water demand

Er01 

- Security Error High Voltage 1. It may also intervene with the system off;

Er02 

- Security Error High Voltage 2. It can only intervene if the Combustion fan is active;

Er03 

- Extinguishing for low exhaust temperature or missing light in the brazier;

Er04 

- Extinguishing for water over temperature;

Er05 

- Extinguishing due to high exhaust temperature;

Er06 

- Pellet Thermostat open (flame return from the brazier);

Er07 

- Encoder Error. The error may occur due to lack signal from Encoder;

Er08 

- Encoder Error. The error can occur due to problems of adjustment of the number of revolutions;

Er09 

- Water pressure low;

Er10 

- Water pressure high;

Er11 

- Clock Error. The error occurs due to problems with the internal clock;

Er12 

- Extinguishing for ignition failure;

Er15 

- Extinguishing due to power failure for more than 50 minutes;

Er16 

- RS485 communication error (Display);

Er17 

- Adjusting the Air Flow Failed;

Er18 

- No more Pellet in the bunker;

Er23 

- Boiler probe or Back boiler probe or probe Buffer open;

Er25 

- Engine cleaning brazier broken;

Er26 

- Engine cleaning broken;

Er27

 - Engine cleaning 2 broken;

Er39 

- Sensor Flowmeter broken;

Er41 

- Minimum air flow in Check Up is not reached;

Er42 

- Maximum air flow exceeded;

Er44 

- Open door error;

Er47 

- Error Encoder Auger: missing signal Encoder;

Er48 

- Error Encoder Auger: Auger regulation speed not achieved;

Er52 

- Error Module I/O I2C;

Er57 

- Test ’Forced Draught High’ in Check Up fail;

Service 

- Service error. It notifies that the planned hours of functioning is reached. It is necessary to call for service.

ALARMS

CONTROL PANEL: USE AND FUNCTIONS

Содержание ECOSTAR 12

Страница 1: ...ECOSTAR 12 18 24 30 35 KW Pellet BOILER Assembly and exploitation manual Mareli Systems ECOSTAR AUTO 12 18 24 30 35 KW Pellet BOILER Assembly and exploitation manual...

Страница 2: ...ouroromissions Anyinterventionorreplacementthatismadebyunauthorizedpeopleorusingnonoriginalspare partsfortheproductcanberiskyfortheuserandreleasethecompanyfromallliability Mostsurfacesoftheboilerareex...

Страница 3: ...ocess no agglutinate agents glues resins and others are added Actual ly the integrity of the pellets is guaranteed by the lignite a natural ingredient contained in the wood itself While the wood has a...

Страница 4: ...12 12 12 Electrical consumption V Hz 60 310 60 310 60 310 60 310 60 310 Electrical supply V Hz 230 50 230 50 230 50 230 50 230 50 Water jacket capacity L 30 48 48 65 65 Working pressure bar 0 5 2 0 0...

Страница 5: ...lectrical supply V Hz 230 50 230 50 230 50 230 50 230 50 Water jacket capacity L 38 38 50 50 50 Working pressure bar 0 5 2 0 0 5 2 0 0 5 2 0 0 5 2 0 0 5 2 0 Working at environment temperature C 5 40 5...

Страница 6: ...he back of the wall Minimum distances from the wall to the boiler should be at least 400 mm The mini mum space in front of the fireplace should be 1500 mm The minimal distance of the boiler from combu...

Страница 7: ...7 Mareli Systems CHECK ITEMS BEFORE INSTALLATION Chimney exit Chimney Connection to chimney Connection to the boiler Security distances The floor Inlet air The chimney revision door...

Страница 8: ...pped with water serpentine and a solar panel For economy and efficiency of the system and a constant availability of cheap hot water a qualified assembly of the automatic shifter controlling the ther...

Страница 9: ...mechanical wear and to the heat coming from the combustion products and condensation To be kept away from flammable materials The recommended chimney draft at work from 12 20 Pa Horizontal sections mu...

Страница 10: ...Systems 3 4Typesofconnectiontothechimney Chimney exit Moisture channel Chimney Thermal insulation External wall Connection to chimney Flue gas connection T connection The chimney revision door Heat g...

Страница 11: ...hould be done only when cold The cleaning of the combustion chamber must be carried out daily For this purpose make sure the fireplace has ceased operation and is completely cold Pull up the combustio...

Страница 12: ...12 Mareli Systems ECOSTAR Cleaning the glass Use an non abrasive cloth Cleaning the pellet bunker Clean the flue gas outlet Combustion chamber Clean the ashtray Revision door...

Страница 13: ...13 Mareli Systems HOT WATER 230V 50HZ ECOSTAR AIR INTAKE EXHAUST FAN SAFETY VALVE PUMP COLD WATER Combustion chamber Clean the ashtray 2020 VERSION...

Страница 14: ...14 Mareli Systems CLEANING THE GLASS USE A NON ABRASIVE CLOTH ECOSTAR AUTO...

Страница 15: ...15 Mareli Systems CLEANING THE PELLET TANK ECOSTAR AUTO...

Страница 16: ...16 Mareli Systems Left inspection door Right inspection door ECOSTAR AUTO ECOSTAR AUTO ECOSTAR ECOSTAR...

Страница 17: ...17 Mareli Systems 230V 50HZ PUMP 2 PUMP COLD WATER HOT WATER OUTLET EXHAUST FAN Safety valve ECOSTAR AUTO...

Страница 18: ...18 Mareli Systems CLEANING THE ASH CONTAINER 1 ECOSTAR AUTO 24 30 35 KW...

Страница 19: ...19 Mareli Systems CLEANING THE ASH CONTAINER 2 ECOSTAR AUTO 24 30 35 KW...

Страница 20: ...20 Mareli Systems CLEANING THE ASH CONTAINER 3 ECOSTAR AUTO 24 30 35 KW...

Страница 21: ...21 Mareli Systems CLEANING THE ASH CONTAINER ECOSTAR AUTO 12 18 KW...

Страница 22: ...f the fireplace may fall hot burning particles as hot ash and small particles burning coal which could lead to a fire in the heated room It is therefore necessary that the product always works with a...

Страница 23: ...h exhaust temperature Er06 Pellet Thermostat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to pro...

Страница 24: ...510 Product code VISUALIZATIONS USER MENU 1 Combustion Management Power In this menu is possible to modify the combustion power of the system It can be set in automatic or manual modality In the first...

Страница 25: ...nday and then set the switching on and off times Monday ON OFF 09 30 11 15 V 00 00 00 00 00 00 00 00 Monday____________ Tuesday Wednesday Thrusday Friday Mon Fri Sat Sun USER MENU 2 Menu is accessed b...

Страница 26: ...ystems K400 TOUCH SCREEN DISPLAY 1 HOMEPAGE Errors Code Date Time HOMEPAGE 1 2 Main Temperature Main Thermostat Functioning State ON OFF Settings Display Info Chrono 11 24 Fri 14 Oct 2016 65 21 C IGNI...

Страница 27: ...3 Auger Aux1 Pump 1 Aux1 Pump 2 Aux3 HOMEPAGE 2 2 L6 L7 L8 System activity LEDS The Quick visualization of the system main function is accessed through a vertical swipe to the top side of the screen S...

Страница 28: ...Oct 2016 65 21 C IGNITION Er 01 Er10 10 50 11 20 11 20 11 20 11 20 Er 53 Er 53 Er 53 Er 53 Error List By clicking on you can see the errors stored by date time and description Scroll to unlock Error 1...

Страница 29: ...nical personnel Settings Menu 12 18 Ven 14 Ott 2016 28 22 C RECUPERO ACCENSIONE Er52 COMBUSTION HEATING REMOTE PANEL MANUAL LOADING RESET SERVICE Setting Menu 11 24 Ven 14 Ott 2016 65 C IGNITION Er 01...

Страница 30: ...05 15 30 00 45 15 02 03 05 04 06 00 15 45 30 00 To edit the time slots press on the corresponding Frame Time Scroll Up or Down to change the System on off Time 5 INTERNAL MENU STRUCTURE Potenza Pelle...

Страница 31: ...ontrol panel is 17 and subsequently the others according to the number provided by the system Control panel restart this function allows the control panel to be restarted Sound this function allows th...

Страница 32: ...30 V GND S5 IN5 32 31 V VC 34 33 GND S6 IN6 36 35 GND S4 IN7 CN1 RS232 RS485 POWER CABLE COMBUSTION FAN IGNITER SAFETY AUGER PUMP SAFETY THERMOSTAT WATER PROTECTION RETURN FLAME PRESSURE SWITCH EXHAU...

Страница 33: ...49 48 51 50 52 54 53 AUX 3 COM N O GND S9 GND S10 S11 Vc V IN 9 IN 10 11 POWER CABLE COMBUSTION FAN PUMP 1 IGNITER WATER OVERHEATING PROTECTION AUGER THREE WAY VALVE OR PUMP 2 DISPLAY EXHAUST PROBE R...

Страница 34: ...34 Mareli Systems...

Страница 35: ......

Страница 36: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems I...

Отзывы: