FRIIA HCS & FRIIA HCS PLUS
FRIIA HOT/COLD/SPARKLING
COUNTER CUT-OUT WITH DRIP TRAY
FRIIA HCS
1000865
FRIIA HCS PLUS
1000867
VENTILATION REQUIREMENTS
FRONT VENTILATION:
Ventillation grilles cut out of standard cabinet door.
SIDE VENTILATION:
Ventillation grilles cut out of standard 600mm
cabinet. Grilles may be fitted on either side as long as they ventilate
into an open unobstruted area.
BASE VENTILATION:
Ventilation grilles cut in base panel and base
plinth, a grille must also be cut out at the top of the cabinet.
• At least 2 x vents 260mm/10.2” w x 65mm/2.5 h
UNPACKING INSTRUCTIONS
• The chiller must be handled only in a vertical position. Transporting
the appliance in a horizontal position can cause severe damage to
the refrigerator.
• Remove the exterior and interior packing. Packing materials
(especially any plastic bags) should be stored out of the reach
of children, as a potential source of danger. When disposing
packaging parts, please follow current regulations on the matter,
separating carton from plastic parts.
• Always check that the equipment that is delivered corresponds to
the model indicated in the accompanying document.
• The equipment is shipped in a cardboard box. Once the packaging
has been removed, check the equipment has not been damaged in
transit; if damage is found, notify the carrier.
ELECTRICAL INSTALLATION PROCEDURE
When installing the machine, always observe the local regulations and
standards. The appliance is supplied with a moulded power cord. A
suitable mains power supply socket should be available within easy
access of the appliance so that it can be disconnected easily after
install. The standard machines are supplied with a UK 3-pin plug.
For EU models a 2-pin CEE-7 plug will be supplied. US models will be
supplied with the suitable plug. A suitable mains power supply socket
should be available within easy access of the appliance so that it
can be disconnected easily after install. The wires from the font are
terminated in a Mini Fit connector which will plug into a similar Mini Fit
connector mounted on the top lid of the undercounter boiler.
PLUMBING INSTALLATION PROCEDURE
• Ensure that the equipment is installed according to local plumbing &
water regulations.
• Fit a stop valve on a cold water line and attach a 3/8” BSP male
fitting, (eg. 3/4” x 1/2” 311 or washing machine type stop valve).
• Connect water supply lines following the installation drawings, as
per installation guide (starting page 14).
• In case filter systems are used verify that they satisfy the
requirements of the legislation in force.
• If the filter is new, turn on water and flush at least 10 liters (2.5
gallon) through the filter before to connect it to the cooler; if the
filter is a used one, connect water inlet to the chiller.
• To ensure that the maximum value of pressure of 3 Bar is not
exceeded the chiller integrates a pressure reducer.
• Turn on the water to flush any impurities, dust etc from the inlet
hose and water pipe. Allow several litres through. Especially for new
installations.
OPERATING THE CHILLER/CARBONATOR FOR THE
FIRST TIME
• Before connecting the appliance to the power source, let it stand upright
for approximately 2 hours. This will reduce the possibility of a malfunction.
• Check that all installation procedures have been carried out.
• Ensure water inlet is open.
• Before supplying power to the unit check water and Carbon Dioxide
lines do not leak.
• Plug the chiller into a suitable socket switch ON/OFF switch on the rear
of the chiller to ON position. The “Power ON Status” light will light-up.
• When the unit is on, the carbonation pump starts to fill. The
carbonation device stops when it reaches the maximum level.
• Once water and CO2 are connected, open the vent on top of the
Chiller by pulling the ring. This operation allows the escape of any air
bubbles present inside, which would affect the carbonation adversely.
• On the pressure reducer knob, adjust CO2 pressure to a value
between 50 and 65 PSI (350 and 450 kPa) (3.5 - 4.5 bar). This value
depends on the temperature of the water and on the ambient
temperature. The temperatures correspond to the CO2 pressure.
• To enable filling the lines, open the two lines in the following order:
cold sparkling water and cold natural water, until the flows appear
regular and without the presence of air, in each case deliver and
discharge at least 5 liters of water from each line.
• At this point you can dispense water.
369
437
600
600
100 min.
275
200
Applies to model(s) 1000850# & 1000851# (where # is blank, or one or more alphanumeric characters)
DRAWN BY
DWG NO.:
PANEL REMOVAL
DESCRIPTION:
PJT 20-08-14
187
C.O.
FRIIA Assembly (in cabinet)
31.5”/
800mm
17.5”/
444mm
9.7”/
247mm
17.9”/
455mm
8.5”/
210mm
10.2”/
259mm
4.1”
/
105mm
1.25”/
32mm
3.25”
/82.5mm