FRIIA HCS & FRIIA HCS PLUS

FRIIA HOT/COLD/SPARKLING

COUNTER CUT-OUT WITH DRIP TRAY

FRIIA HCS

 

1000865 

FRIIA HCS PLUS

 

1000867

VENTILATION REQUIREMENTS

FRONT VENTILATION: 

Ventillation grilles cut out of standard cabinet door.

SIDE VENTILATION:

 Ventillation grilles cut out of standard 600mm 

cabinet. Grilles may be fitted on either side as long as they ventilate 
into an open unobstruted area.

BASE VENTILATION:

 Ventilation grilles cut in base panel and base 

plinth, a grille must also be cut out at the top of the cabinet.
•  At least 2 x vents 260mm/10.2” w x 65mm/2.5 h

UNPACKING INSTRUCTIONS

•  The chiller must be handled only in a vertical position. Transporting 

the appliance in a horizontal position can cause severe damage to 
the refrigerator.

•  Remove the exterior and interior packing. Packing materials 

(especially any plastic bags) should be stored out of the reach 
of children, as a potential source of danger. When disposing 
packaging parts, please follow current regulations on the matter, 
separating carton from plastic parts.

•  Always check that the equipment that is delivered corresponds to 

the model indicated in the accompanying document.

•  The equipment is shipped in a cardboard box. Once the packaging 

has been removed, check the equipment has not been damaged in 
transit; if damage is found, notify the carrier.

ELECTRICAL INSTALLATION PROCEDURE

When installing the machine, always observe the local regulations and 
standards. The appliance is supplied with a moulded power cord. A 
suitable mains power supply socket should be available within easy 
access of the appliance so that it can be disconnected easily after 
install. The standard machines are supplied with a UK 3-pin plug. 
For EU models a 2-pin CEE-7 plug will be supplied. US models will be 
supplied with the suitable plug. A suitable mains power supply socket 
should be available within easy access of the appliance so that it 
can be disconnected easily after install. The wires from the font are 
terminated in a Mini Fit connector which will plug into a similar Mini Fit 
connector mounted on the top lid of the undercounter boiler.

PLUMBING INSTALLATION PROCEDURE

•  Ensure that the equipment is installed according to local plumbing & 

water regulations.

•  Fit a stop valve on a cold water line and attach a 3/8” BSP male 

fitting, (eg. 3/4” x 1/2” 311 or washing machine type stop valve).

•  Connect water supply lines following the installation drawings, as 

per installation guide (starting page 14).

•  In case filter systems are used verify that they satisfy the 

requirements of the legislation in force.

•  If the filter is new, turn on water and flush at least 10 liters (2.5 

gallon) through the filter before to connect it to the cooler; if the 
filter is a used one, connect water inlet to the chiller.

•  To ensure that the maximum value of pressure of 3 Bar is not 

exceeded the chiller integrates a pressure reducer.

•  Turn on the water to flush any impurities, dust etc from the inlet 

hose and water pipe. Allow several litres through. Especially for new 
installations.

OPERATING THE CHILLER/CARBONATOR FOR THE 

FIRST TIME

•  Before connecting the appliance to the power source, let it stand upright 

for approximately 2 hours. This will reduce the possibility of a malfunction.

•  Check that all installation procedures have been carried out.
•  Ensure water inlet is open.
•  Before supplying power to the unit check water and Carbon Dioxide 

lines do not leak.

•  Plug the chiller into a suitable socket switch ON/OFF switch on the rear 

of the chiller to ON position. The “Power ON Status” light will light-up.

•  When the unit is on, the carbonation pump starts to fill. The 

carbonation device stops when it reaches the maximum level.

•  Once water and CO2 are connected, open the vent on top of the 

Chiller by pulling the ring. This operation allows the escape of any air 
bubbles present inside, which would affect the carbonation adversely.

•  On the pressure reducer knob, adjust CO2 pressure to a value 

between 50 and 65 PSI (350 and 450 kPa) (3.5 - 4.5 bar). This value 
depends on the temperature of the water and on the ambient 
temperature. The temperatures correspond to the CO2 pressure.

•  To enable filling the lines, open the two lines in the following order: 

cold sparkling water and cold natural water, until the flows appear 
regular and without the presence of air, in each case deliver and 
discharge at least 5 liters of water from each line.

•  At this point you can dispense water.

 369 

 437 

 600 

 600 

 100 min. 

 275 

 200 

Applies to model(s) 1000850# & 1000851# (where # is blank, or one or more alphanumeric characters)

DRAWN BY

DWG NO.:

PANEL REMOVAL

DESCRIPTION:

PJT 20-08-14

187

C.O.

FRIIA Assembly (in cabinet)

 31.5”/

800mm

  

 17.5”/

444mm

  

 

9.7”/

247mm

 

17.9”/

455mm

 8.5”/

210mm

   10.2”/

259mm

 

 

4.1”

/

105mm

 

1.25”/

32mm

 3.25”

/82.5mm