![Marco FILTRO SHUTTLE 1000650 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/marco/filtro-shuttle-1000650/filtro-shuttle-1000650_instructions_1726528003.webp)
1900062
REV.2
Page 3 of 4
Note : Default settings may vary depending on local connection factors, if required recalibration can be
carried see Setting Brew Water Volumes/Water Flow Times section.
OPERATION:
When the machine has enough water to brew coffee and is at the correct
temperature, the Ready To Brew LED will glow. A brew can be selected at this
point.
Place single filter paper into brew basket, use the 2 wire flaps to hold the filter
paper in place. Add the required weight of coffee.
Slide Brew basket into the guiderails and push fully home.
Ensure your Urn is in place under the basket and that the hole in the basket is
lined up with the centre of
the urn’s inlet funnel. The Filtro Shuttle is designed to
accommodate the Marco Urn, Part number “1700174 Insulated Urn 6L Shuttle”
Select the correct brew on the control panel by pressing the required Brew
Button. Press the switch until the yellow LED illuminates. N.B. If you make a
mistake press the Power Button to turn the machine off. Wait 3 seconds and
turn back on again. Select the correct brew.
After brewing, remove the filter paper with the spent grinds when the basket can
freely move and dripping has stopped.
Once the brew is completed the brew basket will remain locked for a further 2
minutes to allow the remaining water in the brew basket to filter through. This
basket lock will be an audible click and is linked to the Brew Button LED.
Setting Brew Water Volumes/Water Flow Time
With the Filtro Shuttle you may programme (Calibrate) each of the Brew Buttons to
have different Water volume and Overall Brew time settings or to disable buttons.
Contact [email protected] for more information.
Pulse brewing mode:
The Filtro Shuttle will operate in a Pulse Brewing mode. For more details about
Pulse brewing mode contact [email protected] for more information.
Troubleshooting
: The Power LED will indicate failures as follows.
No of flashes Symptom
Action required
2
Water
level
below
elements.
May take 10-15 minutes to fill at
low pressure
Check water pressure, if this is OK - call
service agent.
3
Temperature sensor failure)
Call service agent
4
Water not heating
Call service agent
5
Temperature sensor failure
Call service agent
6
Machine not filling
Check water pressure. If this is OK and
the machine has not returned to normal
operation after 15 min
– call service
agent