TUBULAR FONT WITH ECOSMART UNDERCOUNTER  

WATER BOILERS

TUBULAR FONT WITH ECOSMART UC4, UC10 & UC45

COUNTER CUT-OUT

TUBULAR FONT

 

1000584

TUBULAR FONT WITH DRIP TRAY 

1000585

ECOSMART UC4

 

1000750

ECOSMART UC10

 

1000752

ECOSMART UC45

 

1000754

VENTILATION REQUIREMENTS 

50mm/1.9” clearance required at each side and back of 

machine if installed in an enclosed cabinet. 

ELECTRICAL INSTALLATION PROCEDURE

When installing the machine, always observe the local 

regulations and standards. The standard machine is 

supplied with a UK 3-pin plug. For EU models a 2-pin CEE-7 

plug will be supplied. US models will be supplied with the 

suitable plug. A suitable mains power supply socket should 

be available within easy access of the appliance so that it 

can be disconnected easily after install. The wires from the 

font are terminated in a Mini Fit connector which will plug 

into a similar Mini Fit connector mounted on the top lid of 

the undercounter boiler.

PLUMBING INSTALLATION PROCEDURE

•  Ensure that the equipment is installed according to local 

plumbing & water regulations.

•  Mains water pressure required (limits): 14.5 - 145psi  

(100 - 1000kPa, 0.1 - 1MPa).

•  Requires inline water filter within your water 

specifications.

•  The machine is supplied with a 3/4“ BSP connection.
•  Turn on the water to flush any impurities, dust etc 

from the inlet hose and water pipe. Allow several litres 

through. Especially for new installations. Connect the 

hose to the inlet valve of the boiler. Make sure a sealing 

washer is fitted.

•  Turn on water and check for leaks.

•  If the overflow vent is plumbed it must be plumbed with  

a tundish device.

•  This equipment must be installed with adequate 

backflow protection to comply with all applicable 

federal, state and local codes.

OPERATING BOILER FOR THE FIRST TIME

•  Check that all installation procedures have been  

carried out.

•  Ensure water valve is on.
•  Plug boiler appropriate electrical supply and press 

power button on the front of the machine marked 

‘Power’.

•  The “power on” light will glow green and the machine will 

fill to a safe level, above the elements, before heating.

•  The “Ready/Status” light will cycle two red flashes while 

the machine is filling to the safe level.

•  Whilst the machine is above the safe level and filling,  

the “Ready/Status” light will remain blank.

•  The “Ready/Status” light will glow green when the 

machine is both full and up to normal operating 

temperature.

•  The boiler is now ready for use.
•  The font is simply activated by pressing the button on 

the top of the font.

NOTE: Because the boiler is electronically controlled no 

priming is necessary. The element cannot switch on until  

a safe level of water is reached.

2”/

50mm*

2”/

50mm

* Required for ventilation 

if the machine is installed 

in an enclosed cabinet.

* Hosing should 

be trimmed to 

ensure continuous 

drop from font 

to boiler

23”/

585mm 

>27.6”/

700mm 

15.5”/

395mm

2”/

50mm

11.9

”/

303mm 

4.5”/

114mm 

Ø

 

1.3”/

32mm

Water 

Power 

Vent

Boiler Connections 

to Font

6.3”/

161mm 

min 5.1”

/

130mm

6.1”/

156mm 

23”/

585mm  

15.5”/

395mm

2”/

50mm

11.9

”/303mm 

* Hosing should 

be trimmed to 

ensure continuous 

drop from font 

to boiler

4.5”/

114mm 

Ø

 

1.3”/

32mm

Boiler Connections to Font

Water 

Power 

Vent

2”/

50mm*

2”/

50mm

* Required for ventilation 

if the machine is installed 

in an enclosed cabinet.

>27.6”/

700mm 

min 5.1”/

130mm*

6.

1”

/

156mm 

2”/

50mm*

2”/

50mm

* Required for ventilation 

if the machine is installed 

in an enclosed cabinet.

* Hosing should 

be trimmed to 

ensure continuous 

drop from font 

to boiler

23”/

585mm 

>27.6”/

700mm 

15.5”/

395mm

2”/

50mm

11.9

”/

303mm 

4.5”/

114mm 

Ø

 

1.3”/

32mm

Water 

Power 

Vent

Boiler Connections 

to Font

6.3”/

161mm 

min 5.1”

/

130mm

6.1”/

156mm 

5.5

”/

140mm 

 

* Required for ventilation 

if the machine is installed 

in an enclosed cabinet.

26.2”/

667mm  

19.4”/

495mm

2”/

50mm

11.9

”/303mm 

* Hosing should 

be trimmed 

to ensure 

continuous 

drop from 

font to boiler

4.5”/

114mm 

6.3”/

161mm 

Ø

 

1.3”/32mm

Boiler Connections 

to Font

Dispense 1

Font #1 Connection

Vent

Dispense 2

2”/

50mm*

2”/

50mm

min 5.1”/

130mm

6.1”/

156mm 

5.5

”/

140mm 

2”/

50mm*

2”/

50mm

* Required for ventilation 

if the machine is installed 

in an enclosed cabinet.

* Hosing should 

be trimmed to 

ensure continuous 

drop from font 

to boiler

23”/

585mm 

>27.6”/

700mm 

15.5”/

395mm

2”/

50mm

11.9

”/

303mm 

4.5”/

114mm 

Ø

 

1.3”/

32mm

Water 

Power 

Vent

Boiler Connections 

to Font

6.3”/

161mm 

min 5.1”

/

130mm

6.1”/

156mm 

5.5

”/

140mm 