Marco 162 001 1B Скачать руководство пользователя страница 3

PRODUCT DESCRIPTION

Self-priming electric pump for transfer of fresh or salt water with flexible impeller of nitrile 
rubber which allows the problem-free transit of small particles. 

The electric pump must be connected to a 110VAC/60Hz power. The pump must be 
protected by a suitable rated fuse.

The pump has been designed for continuous use. 

ELECTRICAL CONNECTIONS

OPERATING CYCLE

AMBIENT CONDITIONS

TECHNICAL DETAILS

APPLICATIONS

There are numerous fields of applications for the pump, however only exclusively with 
the allowed liquids mentioned.

- water transfer
- boat bilge water transfer

A

D

E

C

B

F

CODE

TYPE

FLOW RATE  PRESSURE

VOLT

FUSE

WEIGHT

P.CS x CART.

162 001 1B

UP1/AC

1

110

9,5 gpm

15 psi

5 A

18,7 lb

©                    S.p.A.

TEMPERATURE:

 min.-10°C 14°F-max.60°C 140°F  

RELATIVE HUMIDITY:

 max. 90 %

WARNING: 

the above indicated temperature ranges are applicable to all components 

of the pump and these limits must be respected in order to avoid any possible 
damage or malfunctioning.

Содержание 162 001 1B

Страница 1: ...03 05 13 Rev 00 S p A INSTRUCTIONS FOR USE SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING VARIOUS LIQUIDS 162 001 1B UP1 AC 110 V...

Страница 2: ......

Страница 3: ...BIENT CONDITIONS TECHNICAL DETAILS APPLICATIONS There are numerous fields of applications for the pump however only exclusively with the allowed liquids mentioned water transfer boat bilge water trans...

Страница 4: ...so as per the precautions listed below The packaging material is not in any way polluting or dangerous and does not require any special environmental disposal precautions Disposal should be carried ou...

Страница 5: ...NING THE MOTOR IS NOT EXPLOSION PROOF Do not install the pump where flammable vapours or gases may be present Install it in an accessible place for inspection The pump is IP55 protection rated It is g...

Страница 6: ...fore start up It is also advisable to add before running the pump a drop of lubricating oil inside the pump only Air leak at the suction pipe due to the following reasons Possible cuts in the pipe ina...

Страница 7: ...purchase on production of the appropriate sales invoice 2 Should the original sales invoice not be available then the 2 year warranty period will be valid from date of production 3 The Warranty become...

Страница 8: ...1 RUBBER LIP SEAL 12 1 IMPELLER 13 1 O RING 14 1 TOP PLATE 15 4 SCREW Art Q ty Description 1 MOTOR 2 1 JOINT 3 1 HEADLESS SCREW 4 1 FLANGE 5 2 SCREW 6 SCREW 7 2 BALL BEARING 8 1 SHAFT 1 4 EXPLODED VIE...

Страница 9: ...DIMENSIONS P1 112 142 80 90 45 101 316 120 26 27 5 32 16 84 17 129 187 71 16 104 191 S p A...

Страница 10: ...hines for the domestic use and similar uses Particular applications of electric pumps with liquids that do not exceed 35 C EN50081 1 03 93 Generic emission standard residental commercial and light ind...

Страница 11: ...NOTES...

Страница 12: ...f MARCO S p A reproduction prohibited All rights reserved For further information visit our web site www marco it Marco S p A Via Mameli 10 25014 Castenedolo Brescia Italy tel 39 030 2134 1 Fax 39 030...

Отзывы: