![Marco 1000660 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/marco/1000660/1000660_instructions-manual_1726487002.webp)
SAFETY:
This appliance must be earthed. If the moulded plug supplied is not used then ensure that
the green/yellow cable is connected to a suitable earth.
Risk of flooding. The hose supplied with this unit is non-toxic food quality tested to 190psi.
However, a hose is not a permanent connection. It is, therefore, advisable to switch off
boiler and close the stopcock valve when boiler is not in use, e.g. overnight, weekends etc.
Risk of scalding. Beware of accidentally operating the water drawoff tap or push button
especially when cleaning the front of the boiler.
The utmost care has been taken in the manufacture and testing of this unit. Failure to
install, maintain and / or operate this boiler according to the manufac
turer’s instructions
may result in conditions that can cause injury or damage to property. If in any doubt about
the serviceability of the boiler always contact the manufacturer or your own supplier for
advice.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory, or mental capabilities, or lack of experience and knowlodge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
In the event any wires are damaged, such wires can only be replaced by experts or
professional afterservice staff from the manufacturer,afterservice department or similiar
function departments.
INSTALLATION DETAILS:
General ins talla tion:
To be installed in locations where temperatures are between 5°C and 35°
Ensure that the ap pliance is p laced o n a flat horizonta l surface.
Ensure that the ap pliance is insta lled where it can be ob se rved b y tra inied
personell.
Electrical installation:
Electrical specification: 2.8kW 200-230Vac 50Hz
A moulded 13A plug is factory fitted. A suitable 13A outlet is all that is required.
For 200V installation ensure appropriate connection to suitable supply.
Plumbing insta llation proce dure:
Mains water pressure required (limits): 14.5-145psi (100-1000kPa)
Fit a stop Valve on a cold water line and attach a 3/4" BSP male fitting,
(e.g. 3/4" x 1/2" 311 or washing machine type stop valve).
Where a flexible hose is to be used in the instiiation please use the new hose set supplied. Do
not use old flexible hose sets for the instillation of this appliance.
Connect straight tailpiece of the hose to the stop valve fitting. Make sure that the pre-attached
sealing washer is fitted.
Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow
several gallons through.
Connect right-angled tailpiece of the hose to the inlet valve of the boiler (again 3/4" BSP).
Make sure the sealing washer is fitted here also.
Turn on water and check for leaks.
NOTE
: Using a non-foodgrade hose (e.g. a washing machine hose) will usually result in off-
tastes & smells in the water, and can possibly be toxic.