Marco 1000660 Скачать руководство пользователя страница 2

 

SAFETY: 

 

  This appliance must be earthed.  If the moulded plug supplied is not used then ensure that 

the green/yellow cable is connected to a suitable earth. 

  Risk of flooding.  The hose supplied with this unit is non-toxic food quality tested to 190psi.  

However, a hose is not a permanent connection.  It is, therefore, advisable to switch off 
boiler and close the stopcock valve when boiler is not in use, e.g. overnight, weekends etc. 

  Risk of scalding.  Beware of accidentally operating the water drawoff tap or push button 

especially when cleaning the front of the boiler. 

  The utmost care has been taken in the manufacture and testing of this unit.  Failure to 

install, maintain and / or operate this boiler according to the manufac

turer’s instructions 

may result in conditions that can cause injury or damage to property.  If in any doubt about 
the serviceability of the boiler always contact the manufacturer or your own supplier for 
advice.

 

  This appliance is not intended for use by persons (including children) with reduced 

physical, sensory, or mental capabilities, or lack of experience and knowlodge, unless they 
have been given supervision or instruction concerning use of the appliance by a person 
responsible for their safety. 

  Children should be supervised to ensure that they do not play with the appliance. 

  In the event any wires are damaged, such wires can only be replaced by experts or 

professional afterservice staff from the manufacturer,afterservice department or similiar 
function departments. 

 

INSTALLATION DETAILS:  

 
General ins talla tion:  

  To be installed in locations where temperatures are between 5°C and 35° 

  Ensure that the ap pliance is p laced o n a flat horizonta l surface.

 

  Ensure that the ap pliance is insta lled where it can be ob se rved b y tra inied 

personell. 

 

 

 

Electrical installation:  

  Electrical specification: 2.8kW 200-230Vac 50Hz  

  A moulded 13A plug is factory fitted. A suitable 13A outlet is all that is required. 

  For 200V installation ensure appropriate connection to suitable supply. 

 

Plumbing insta llation proce dure:  

  Mains water pressure required (limits): 14.5-145psi (100-1000kPa) 

  Fit a stop Valve on a cold water line and attach a 3/4" BSP male fitting, 

  (e.g. 3/4" x 1/2" 311 or washing machine type stop valve). 

  Where a flexible hose is to be used in the instiiation please use the new hose set supplied. Do 

not use old flexible hose sets for the instillation of this appliance.  

  Connect straight tailpiece of the hose to the stop valve fitting. Make sure that the pre-attached 

sealing washer is fitted. 

  Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow 

several gallons through. 

  Connect right-angled tailpiece of the hose to the inlet valve of the boiler (again 3/4" BSP). 

Make sure the sealing washer is fitted here also. 

  Turn on water and check for leaks. 

 

NOTE

: Using a non-foodgrade hose (e.g. a washing machine hose) will usually result in off-

tastes & smells in the water, and can possibly be toxic. 
 

 

Содержание 1000660

Страница 1: ...e 9 Instruction for use in German Page 13 Instruction for use in Russian Permissible mains inlet water pressure Minimum 100kPa 0 1MPa 1bar 14 5psi Maximum 1000kPa 1MPa 10bar 145psi Marco Beverage Syst...

Страница 2: ...ed by experts or professional afterservice staff from the manufacturer afterservice department or similiar function departments INSTALLATION DETAILS General installation To be installed in locations w...

Страница 3: ...2L 5L Display 10L Display Figure 1 Machine User Interface NOTE Because the boiler is electronically controlled no priming is necessary The element cannot switch on until a safe level of water is reach...

Страница 4: ...ch scale as possible by hand paying particular attention to level probes White plastic with steel tab Be very careful not to damage any attachments Use ScaleKleen Marco part No 8000270 or similar Foll...

Страница 5: ...ression d aspiration principale autoris e Minimum 100 kPa 0 1MPa 1 bar 14 5 psi Maximum 1000 kPa 1 MPa 10 bar 145 psi Marco Beverage Systems Limited 63d Heather Road Sandyford Industrial Estate Dublin...

Страница 6: ...amusent pas avec l appareil En pr sence de c bles endommag s ne les faites remplacer qu en faisant appel un professionnel ou un agent du service apr s vente du fabricant du revendeur ou autres service...

Страница 7: ...onique aucun amor age n est n cessaire La mise en route n intervient pas tant que le niveau d eau n atteint pas une valeur conforme avec la s curit Fonctionnement mode ECO Tous les Ecoboilers utilisen...

Страница 8: ...nt tr s attention aux sondes de niveau plastique blanc avec languette en acier Prenez soin de ne pas endommager les fixations Utilisez ScaleKleen pi ce Marco N 8000270 ou similaire Respectez les instr...

Страница 9: ...r USA Zul ssiger Eingangswasserdruck Minimum 100 kPa 0 1 MPa 1 bar 14 5 psi Maximum 1000 kPa 1 MPa 10 bar 145 psi Marco Beverage Systems Limited 63d Heather Road Sandyford Industrial Estate Dublin 18...

Страница 10: ...rden Kinder m ssen beaufsichtigt werden damit sie nicht mit dem Ger t spielen Wenn Dr hte besch digt sind d rfen diese nur von Fachleuten oder professionellem Kundenservicepersonal des Herstellers der...

Страница 11: ...hrend das Ger t ber den sicheren F llstand hinaus gef llt ist Die Lampe Bereit Status leuchtet gr n wenn das Ger t gef llt ist und normale Betriebstemperatur hat Warten Sie bei 2 l ca 10 Minuten Wart...

Страница 12: ...atursensorfehler OSK Servicevertreter anrufen 6 Das Ger t wird nicht aufgef llt berpr fen Sie den Wasserdruck und rufen Sie Ihren Servicevertreter an falls er in Ordnung ist WARTUNG Dieses Ger t wurde...

Страница 13: ...0666 100 0 1 1 14 5 1000 1 10 145 Marco Beverage Systems Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Systems Limited Shire House Strixton Manor Strixton Wellingboroug...

Страница 14: ...2 8 200 230 AC 50 13 A 13 A 200 Plumbing installation procedure 14 5 145 100 1000 3 4 BSP 3 4 x 1 2 311 3 4 BSP...

Страница 15: ...13 Power 1 2 5 Power Ready power on Ready 96 C 1 2 2 5 Ready 10 Ready Ready 2 10 f 5 15 10 30 2L 5L Display 10L Display 1 Ecoboiler 20 30 Ecoboiler ECO Ready ECO Ecoboiler o ECO 96 C...

Страница 16: ...o o ECO Ready Status 2 3 4 5 6 ScaleKleen Marco part No 8000270...

Страница 17: ......