Need Help? Contact us today (866)568-2770 or [email protected]
Step 4
– Place Into Service
Place the SPuck on a flat surface. If water comes in contact with either
of the water sensors, the SPuck will send an alarm to the MarCELL.
When transmitting the SPuck
’s LED will flash quickly.
Once a SPuck detects the presence of water and sends the alarm
signal, it will be deactivated to preserve battery life. When the water
that caused the alarm is no longer present, the SPuck will
automatically reset after 15 minutes. You can also rearm the SPuck by
making sure the sensors are dry and pressing and releasing the test
button. When the button blinks blue your SPuck is back in service and
ready to detect water again.
NOTE:
The SPucks water detection circuit is designed to be very
sensitive. If the sensors remain wet after the test button press the
SPuck will indicate this by flashing 1 short blue pulse every 5 seconds.
If you see this, please dry the sensors more thoroughly or wait a few
minutes for them to dry off. When the sensor has reset the 1 pulse
flash will stop.
Changing the battery
Turn the SPuck over so the made in the USA label is facing towards
you
Slide the back cover up
¼” – this will take a little force and you will
hear a click
Lift the back cover off
Slide the CR2025 coin cell down and replace it with the new battery. If
this is done properly you will see the button flash 4 times.
Replace the back cover
Technical Specifications
Battery : CR2025 Coin Cell
Radio : 915Mhz ISM band, 19.2k baud
Size : 1.42
” (width) 1.92” (length) 0.40” (height)