3. Update method when the MAIN PCB or network module is replaced (Using a USB flash drive NETWORK MODULE)
3.1. File structure on USB flash drive
MAIN PCB or network module is replaced onto the USB flash drive in the following structure.
After unzipping the files, store them in the root of the same USB flash drive.
Model Area
Download from SDI
ALL
avr_40.prod.update.factory.xxxx.zip
USB flash drive root
+ avr_40.prod.update.factory
+ xxxxxxzz.ota-download
+ heos_40.prod.update.factory
xxxxxx : Model name
zz : Region
3.2. Start the update.
NOTE :
• Remove the LAN cable from this unit when updating.
(Do not connect to a wired or wireless network.)
• The GUI menu setting details and image quality adjustment setting details are initialized when
Firmware Factory Restore is performed. Therefore, take a note of the setting details beforehand and
reconfigure the settings after update.
• Do not remove the USB flash drive until updating is completed.
• Do not turn off the power until updating is completed.
• It takes a maximum of approximately 25 minutes for update to complete.
Once an update is started, normal operations cannot be performed until it is completed.
(1) Press the power operation button to turn off the power, and remove the AC plug from the socket.
(2) Insert the AC plug while pressing buttons "
SOURCE DIRECT
" and "
ENTER
" together, and wait for
more than 3 seconds.
(3) "
All Device USB Update
" is displayed.
•It takes approximately 90 seconds to start up the network device.
(4) Insert the USB flash drive into the USB port.
Download firmware
in USB flash drive.
(5) USB Update starts automatically.
The power indicator lights up in red.
Display during USB update
↓
↓
It takes a maximum of approximately 11 minutes for update to complete.
(6) The unit restarts when update is complete.
b
When update is complete, the folder name on the USB flash drive changes to "
avr_40.prod.update.factory
.
done
". To use the files again, delete the "
.done
" part.
(7) Execute Firmware Factory Restore.
•Press the power operation button to turn off the power, and remove the AC plug from the socket.
• Insert the AC plug while pressing buttons "
POWER
" and "
BACK
" together, and wait for more than 3
seconds.
Display during Firmware Factory Restore
NOTE: If you entered this mode by mistake, do not re-move the AC plug until Firmware Restore is
completed.
The Power indicator LED (red) is lit
↓
↓
It takes approximately 7 minutes for Firmware Factory Restore to complete.
(8) Execute Service Region Settings.
See "
4. Update Method for Service Region Settings (NETWORK MODULE)
(9) Check that the version is the specified version. See "
"
(10) OTA or the USB flash drive to update the firmware to the newest version.
b
We recommend using the firmware update method using OTA.
See "
5. Normal Firmware Update Method from USB Flash Drive (NETWORK MODULE)
" or "
Firmware Update Method from OTA (NETWORK MODULE)
Before Servicing
This Unit
Electrical
Mechanical
Repair Information
Updating
59