3.6. Operation Info Mode
3.6.1. Actions
This mode enables the unit to display the accumulated operating time, power on count and each protection count.
3.6.2. Starting up
While holding down buttons "
ZONE2 SOURCE
" and "
STATUS
" simultaneously, press the power button to turn on the
power.
Select the "
4. OP INFO
" using the "
TUNER PRESET CH+
" button, then press the "
STATUS
" button to confirm.
3.6.3. Operations
Press the "
STATUS
" button after starting up this device in Operation Info mode.
The following information is displayed in the following order.
(a) Accumulated operating time
FLD
O P
T i m e
H
↑ Time display
"
STATUS
"
(b) Power on count
FLD
P . O n
T i m e
↑ Count display
"
STATUS
"
(c) DC / ASO Protection count
FLD
D C :
/ A S O :
"
STATUS
"
(d) Thermal Protection count
FLD
T H M
A :
/ B :
"
STATUS
"
(e) Current Protection count
FLD
C u r r e n t :
"
STATUS
"
(Returns to normal display)
42
Содержание NR1506 /K1B
Страница 8: ...8 Personal notes ...
Страница 120: ...Personal notes Personal notes 120 ...
Страница 137: ...2 FL DISPLAY FLD 018BT021GINK FRONT U4400 PIN CONNECTION GRID ASSIGNMENT q T7 137 ...
Страница 138: ...ANODE CONNECTION 138 ...