3. No Remote Control Reception
Check that you are using a [RC001PMND] remote control and replace the batteries.
Is the switch on the [REMOTE CONTROL] input
output back panel set to [EXTERNAL]?
Only input via the [REMOTE IN] terminal is
received when set to [EXTERNAL].
Only remote control operations are received
when set to [INTERNAL].
Is a square wave input when the power is on and
a switch is pressed on the remote control while it
is pointed towards the device?
DIGITAL PCB : [
N1004 : 4pin
]
SYSTEM uCOM[
U1004 : 26pin
] RC_IN
Check the connection.
Has a contact failure occurred or is a connector
missing?
DIGITAL PCB : [
N1001
] to FRONT PCB : [
N5006
]
Check the connection.
Has a contact failure occurred or is a connector
missing?
POWER PCB : [
N4007
] to FRONT PCB : [
N5008
]
Check the connection.
Has a contact failure occurred or is a connector
missing?
POWER PCB : [
N4005 : 4pin
] to DIGITAL PCB :
[
N1004 : 4pin
]
Check the power supply voltage. FRONT PCB
Does the power supply voltage largely deviate
from 3.3V?
[
N5008 : 2pin
] = +3.3V ± 0.5V
Is a square wave output when the power is on
and a switch is pressed on the remote control
while it is pointed towards the device?
FRONT PCB[
U5001 : 1pin
]
It is likely there is a Front PCB [
U5001
] malfunc-
tion.
Replace the [
U5001
].
Set the switch on the [REMOTE CONTROL] input
output back panel to [INTERNAL].
The System uCOM [
U1004: 26pin
] may be
malfunctioning.
Replace the System uCOM [
U1004
] or the Digital
PCB.
Check if the connection is as indicated in the
wiring diagram and adjust the FFC wiring if
necessary.
If this does not re-establish contact in the wiring,
replace the FFC or the circuit board which the
connectors are mounted on.
Check if the connectors are connected as
indicated in the wiring diagram and adjust the
connections if necessary.
If this does not re-establish contact in the wiring,
replace the Wire Assy unit or the circuit board
which the wires are mounted on.
Check if the connectors are connected as
indicated in the wiring diagram and adjust the
connections if necessary.
If this does not re-establish contact in the wiring,
replace the Wire Assy unit or the circuit board
which the wires are mounted on.
Check each part listed after "
YES
".
There is a [
Q5003
] malfunction if a square wave
is not output to the Front PCB [
Q5003
] collector
in the same way.
Replace the [
Q5003
].
If a square wave is output, check for abnor-
malities in the Power PCB [
S4002, Q5008 and
Q5007
].
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
Before Servicing
This Unit
Electrical
Mechanical
Repair Information
Updating