17
3C
DownLoad failure(Download error (connection failed)
information recived)
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
3D
Failed to acquire the IP Address after transitioning to
the Boot Loader Mode
(AutoIP)
"Turn off and on the power. Updating starts automatically.
Carry out the update in an environment that has little network
load."
3E
Failed to acquire the IP Address after transitioning to
the Boot Loader Mode (TimeOut)
"Turn off and on the power. Updating starts automatically.
Carry out the update in an environment that has little network
load."
•
CX870 system Firmware error codes when rewriting. (Check the ETHERNET unit)
Error Code
Details of Error code
Coping strategies
A0
Net not connected
Check the network connection. Carry out the update in an
environment that has little network load.
A1
Net Connection TimeOut can not get status
Check the network connection. Carry out the update in an
environment that has little network load.
A2
Login failed
Check the network connection. Carry out the update in an
environment that has little network load.
A3
Login failed
Check the network connection. Carry out the update in an
environment that has little network load.
A4
Login failed
Check the network connection. Carry out the update in an
environment that has little network load.
A6
Error receiving response FirmInfo acquisition
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
A7
FirmInfo Get Response TimeOut
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
A8
Net not connected
Check the network connection. Carry out the update in an
environment that has little network load.
A9
Net Connection TimeOut can not get status
Check the network connection. Carry out the update in an
environment that has little network load.
AA
After download request, Login Failed
Check the network connection. Carry out the update in an
environment that has little network load.
AB
After download request, Login Failed
Check the network connection. Carry out the update in an
environment that has little network load.
AC
After download request, Login Failed
Check the network connection.Carry out the update in an
environment that has little network load.
AE
Failure of DownLoad
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
AF
Failure of DownLoad
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
B0
Failure of DownLoad
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
B2
Update error
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
Failure to update, after the move again DM860 itselfe display retry processing
Содержание NA8005
Страница 8: ...Personal notes 8 ...
Страница 24: ...19 Personal notes ...
Страница 38: ...38 Personal notes ...
Страница 43: ...WIRING DIAGRAM 43 ...
Страница 56: ...Personal notes Personal notes 56 ...
Страница 62: ...62 PCM9211 DIGITAL IC42 PCM9211 Block Diagram ...
Страница 63: ...63 PCM9211 Pin Discriptions ...
Страница 66: ...66 CS2000 CP DIGITAL IC43 CS2000 CP Block Diagram ...
Страница 69: ...69 MFI337S3959 DIGITAL IC25 ...
Страница 70: ...70 2 DISPLAY S020 MXS4035A 3 ...