OMI Operations Manual: OMI6800 Series
32
OMI Operations Manual: OMI6800 Series
32
REMOTE POWER SWITCH CONFIGURATION
1. Using a #1 Phillips screwdriver, remove
the 2 Phillips screws indicated in the
figure.
2. Remove the storage cover by lifting it out
of the unit.
3. Using a #1 Phillips screwdriver, remove
the 1 screw retaining the storage bracket.
Then carefully slide the bracket out of the
unit.
4. The DIP switches and switch settings are
now visible.
5.
Reference the “COM1 Function Switch
Setting” label and the chart to set the DIP
switch 6 for AT(Default) or ATX
Function
S_422
(switch 6)
Auto Power ON
(AT Default)
ON
Remote Switch Power
ON (ATX)
OFF
6. Slide the bracket and storage device into
the OMI, securing it with the screw
removed in step 3.
7. Replace the storage cover and secure it