Manson Engineering Industrial SBC-9138 Скачать руководство пользователя страница 7

Stage 7. 

STANDBY MODE - The constant voltage charging 

 
In this stage, the charging voltage at this mode will be 4% less than the Float voltage only for maintaining the capacity. 
The Standby curve (STA) will display with slow flashing. 
 

New Cycle Charge every 18 days 

Charger will start a new cycle charging of bulk to absorption to float every 18 days in either standby or float mode This 
new cycle of charging will refresh the battery to prevent separation of the electrolyte & keep the electrode plates in good 
condition. 
The standby auto new cycle charge per 18 days are designed to keep the battery in good working condition during long 
period of resting of the caravan or back up battery application. 

 

E.  Recondition Charging for wet type battery only 

 
This mode is used to recover  deeply  discharged flooded battery only by high voltage charging (about  10% overcharge 
absorption voltage). You can manual select this mode by simply press and hold 3 seconds the Recondition mode switch 
(3) to set the charger at the beginning of charging operation. The LCD display will show RECOND to represent you have 
selected Recondition mode in this charging cycle and the charging will be conducted after Absorption mode. 
 

 

 
After entered into this mode, the Recondition curve (REC) will display with slow flashing. This will put the charger keep at 
Recondition mode for preset time and then charger will go to Float once completed. 
In  case  you  want  to  cancel  the  Recondition  charge  that  you  selected,  you  can  disable  this  by  press  and  hold  the 
Recondition mode switch (3) for 3 seconds. 
 

Remark:  1.  This mode only can be operated at Flooded battery selected (Battery Selection Switch (4) set to   
 

 

 

position 1 the WET battery) 

 

 

2.  Take special precautions as battery will emit explosive gas during Recondition charge. 

 

F.  Power Level adjustment 

 
End user can set the maximum output current so to make the charger can suitable for different capacity battery 
Make sure the charger is power OFF before adjust the power level. 
Use a small slot type screw driver to select the maximum output current through the Charging Current Selection Switch 
(5). Please refer to the label under the removable door for power level selection. 
LCD display will show the power level by % after restart the charger. 
 
Position 1: 100% of the rated current 
Position 2: 80% of the rated current   
Position 3: 60% of the rated current   
Position 4: 40% of the rated current   
Position 5: 20% of the rated current   
 

 
 
 
 

 
 
 

 
 
 
 

Содержание SBC-9138

Страница 1: ...not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face awa...

Страница 2: ...ting The extensive protection with alarm and LED indications including the thermostatic decrease of charging current to shut down ensure a durable working life span even in harsh conditions for the ch...

Страница 3: ...emovable temperature sensor RED battery clamp Battery positive pole BLACK battery clamp Battery negative pole 8 Removable temperature sensor To increase decrease charging voltage at low high battery t...

Страница 4: ...de a constant voltage DC power 13 3V to the external load connected to the battery and at the same time without over charging the battery B1 Recommended Battery Capacity The following minimum AH capac...

Страница 5: ...t GEL and Charging Current Selection Switch 5 for output current setting default at 100 When install in caravans and similar vehicles the connection to the supply mains is to be in accordance with nat...

Страница 6: ...h slow flashing If the charger cannot go to Absorption mode within 20 hours the charger will automatically goes to Float mode so to prevent over charge the battery This is call safety timer Stage 4 AB...

Страница 7: ...on mode in this charging cycle and the charging will be conducted after Absorption mode After entered into this mode the Recondition curve REC will display with slow flashing This will put the charger...

Страница 8: ...hich is not affected by other cooling or heating source Or you can insert it into the power cable negative battery clamp factory pre mounted The reference temperature of this sensor is 25 C and compen...

Страница 9: ...stuck or not working F5 Faulty battery F6 Battery temp over 60 C as detected by remote sensor F7 short circuit 5 sec shut down otherwise auto recover Remark F7 is for power supply only F8 Reverse pol...

Страница 10: ...onnection Battery type select switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for lo...

Страница 11: ...oise Peak to Peak 200mV Efficiency at WET 230VAC 85 Protections Short Circuit Protection Yes Overload Protection Yes Reverse Polarity Protection by Mosfet Yes Over Temperature Protection Yes OVP Outpu...