Manson Engineering Industrial SBC-9138 Скачать руководство пользователя страница 1

SBC-9138/9238 

Multi- Stage Smart Battery Chargers 

User Manual 

 

Keep this manual in a safe place for quick reference at all times. 

 

This manual contains important safety and operation instructions for correct use of the battery charger. Read through the 

manual and pay special attention to the markings and labels of the charger, battery and equipment connected to the 

battery system. 

 

Pay special attention to these two types of notices used in this manual. 

 

WARNING: 

Failure to heed this warning may cause injury to persons and damage to Equipment. 

 

CAUTION: 

Failure to observe this warning may result in damage to equipment and improper functioning of the Charger. 

 

WARNING: 

 

●  The charger is designed for in-door use. Protect the charger from ingress of water. 
●  This charger is made to charge only properly sized lead acid batteries. 
●  Don't recharging non-rechargeable batteries. 
●  Charging other types of battery or under-sized lead acid batteries may cause fire or explosion. 
●  Install the charger in accordance with all local codes 
●  Do not use the charger if it has been dropped or damaged. 
●  Do not remove casing of the charger, there is no user-serviceable parts inside.   
●  Do not charge the battery on boats. Remove the battery and charge on shore. 
●  Never attempt to charge a frozen battery   
●  Never attempt to charge a damaged battery. 
●  Wear protective goggles and turn your face away when connecting or disconnecting the battery. 
●  Never place the charger on top of a battery. 
●  Never  smoke,  use  an  open  flame,  or  create  sparks  near  battery  or  charger  during  normal  charging  operation  as 

batteries may give out explosive gas. 

●  Do not charge batteries in an enclosure (box- in) due to possible explosion of entrapped explosive gas. 
●  Use of accessory not recommended may cause risk of fire, electric shock. 
●  Disconnect the mains supply before connecting or disconnecting the links to the battery. 
●  If the charger does not work properly or if it has been damaged, unplug its AC and DC connection. 
 

CAUTIONS: 

 
●  Refer to battery manufacturer’s specific recommended values for battery type settings and float voltage setting. 
●  Fix the charger to a solid support via three grooves at the flange of chassis, with three screws or nuts. 
●  Ensure all ventilation ports are not obstructed for efficient fan cooling, keep loose soft material or paper off at the vent 

holes of the charger. 

●  During charging, the battery must be placed in a well ventilated area. 
●  If longer output charging cord is required, make sure the diameter is adequate for the current in given cable length. 

Содержание SBC-9138

Страница 1: ...not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face awa...

Страница 2: ...ting The extensive protection with alarm and LED indications including the thermostatic decrease of charging current to shut down ensure a durable working life span even in harsh conditions for the ch...

Страница 3: ...emovable temperature sensor RED battery clamp Battery positive pole BLACK battery clamp Battery negative pole 8 Removable temperature sensor To increase decrease charging voltage at low high battery t...

Страница 4: ...de a constant voltage DC power 13 3V to the external load connected to the battery and at the same time without over charging the battery B1 Recommended Battery Capacity The following minimum AH capac...

Страница 5: ...t GEL and Charging Current Selection Switch 5 for output current setting default at 100 When install in caravans and similar vehicles the connection to the supply mains is to be in accordance with nat...

Страница 6: ...h slow flashing If the charger cannot go to Absorption mode within 20 hours the charger will automatically goes to Float mode so to prevent over charge the battery This is call safety timer Stage 4 AB...

Страница 7: ...on mode in this charging cycle and the charging will be conducted after Absorption mode After entered into this mode the Recondition curve REC will display with slow flashing This will put the charger...

Страница 8: ...hich is not affected by other cooling or heating source Or you can insert it into the power cable negative battery clamp factory pre mounted The reference temperature of this sensor is 25 C and compen...

Страница 9: ...stuck or not working F5 Faulty battery F6 Battery temp over 60 C as detected by remote sensor F7 short circuit 5 sec shut down otherwise auto recover Remark F7 is for power supply only F8 Reverse pol...

Страница 10: ...onnection Battery type select switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for lo...

Страница 11: ...oise Peak to Peak 200mV Efficiency at WET 230VAC 85 Protections Short Circuit Protection Yes Overload Protection Yes Reverse Polarity Protection by Mosfet Yes Over Temperature Protection Yes OVP Outpu...