background image

Operation 

 

 

Display 

Indications 

Standby

 

Standby Mode 

Steady light on: 

AC connected but charger not yet connected to battery 

      

Blinking light on: 

Battery connected, charger ready for battery selection. User has one minute to select 

battery before charger returns to last selected battery type. 

 

Check & Repair Mode

 

Steady light on: 

For a few seconds for normal battery while charger checking on battery condition. 

Steady light on: for longer than a minute, charger in desulphating repair charging 

ONLY FOR LEAD BATTERY

 

Steady light on: 

For longer time, charger in *desulphate charging. 

Blinking light on: 

When connected to battery showing the battery is not suitable for charge. 

Blinking light on: 

Charger in charging mode longer than 40 hours or more than 8 hours in desulphating 

repair charging of LEAD battery. 

 

Alarm Warning:

   

The alarm warns charging faults check following possible causes   

Steady light on:

 

output connection in reverse polarity or short circuit protection causing no charging/ 

output shutdown.   

In group of 2 flashes pattern:

 Output over-voltage protection & output shut down.   

In group of 3 flashes pattern:

 charger over-temperature protection & output shut 

down.

 

 

Charge Mode: battery Not Full 

 

Steady light on:

 Charging in progress, may be in sulphating, soft start bulk, bulk & 

absorption. 

Battery is less than 70% full and may be in any of the above charging stage. 

 

Float Charge Mode: battery Full

 

Steady light on:

 Charger is in Float mode/ Maintenance pulse mode. 

Battery is fully charged. 

LEAD

 

Steady light on: 

charge battery at room temperature 

Blinkering light: 

charge battery at cold temperature 

AGM 

Steady light on: 

charge battery at room temperature

 

Blinkering light: 

charge battery at cold temperature

 

LiFePO4 

Steady light on: 

charge battery at room temperature

 

Содержание SBC-8188

Страница 1: ...ns important safety and operation instructions for correct use of the battery charger Read through the manual and pay special attention to the markings and labels of the charger battery and equipment...

Страница 2: ...explosive gas Do not charge batteries in an enclosure box in due to possible explosion of entrapped explosive gas Use of accessory not recommended may cause risk of fire electric shock Disconnect the...

Страница 3: ...hen full bulk pulse absorption and free float charge stages Special charging profile for LiFePO4 battery soft bulk bulk then free float stage No auto repair Extensive Protections spark proof short cir...

Страница 4: ...rging of LEAD battery Alarm Warning The alarm warns charging faults check following possible causes Steady light on output connection in reverse polarity or short circuit protection causing no chargin...

Страница 5: ...type change To change the battery type during a charging operation either switch off the AC or reconnect the battery and select the new battery type after self check LEAD AGM Battery After selection o...

Страница 6: ...tion and Repair charge stage for LFP Check Mode and Unchargeable battery A If the Check Mode blinks before or after pressing the Mode button then the battery is not suitable for charging Check the bat...

Страница 7: ...n Voltage for LEAD Low Temp Mode 14 7V 29 4V Absorption Voltage for AGM Low Temp Mode 15 0V 30 0V Construction IP 20 Poly carbonate casing Accessories Detachable leads with crocodile clips and leads w...