![Manson Engineering Industrial SBC-8112 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/manson-engineering-industrial/sbc-8112/sbc-8112_user-manual_1723066004.webp)
SBC-Series Switching Mode Programmable Automatic Charger User Manual
4. OPERATIONS
4.1
Charging Methods
There are 3 charging methods.
A.
Normal Charging
1. Check and set the Dip Switch Control Settings for your battery type: Wet, Seal or AGM Type.
Then set the set the timer T to Off and PS to Off (
Table 3
).
2.
Put the ring/spade connector of your cable to the terminal pole first, then the spring washer and
screw as tight as possible.
3.
Recheck the tightness by jigging the cable and ensuring the spring washers are flat.
4.
Switch on the charger and the LED should light up in green. The charger will Boost Charge the
battery until fully charged up then the charger will switch to Float voltage automatically and the
LED will be Off.
The Charger can be left unattended without worrying about overcharging the battery. In case,
the battery becomes low again, the charger will automatically start the Boost to Float charging
cycle again.
5.
To use the Temperature Compensation Function, plug a PT100 Temperature Sensor (optional
accessory) into the Temperature Sensor Terminal and attach it firmly on the side of the battery
(
FIG. 3
).
For 12V system( SBC-8112, 8125 ), it will regulate at -20mV/degree C increase.
For 24V system( SBC-8215 ), it will regulate at -40mV/degree C increase.
When the battery's temperature is about 60 degree C, the LED will be red and the charger will
stop charging the battery. Turn off the charger to reset the charger.
(
FIG. 3
)
P.3
SBC - 8112 / 8125
( 12V system )
SBC - 8215
( 24V system )
13.9V
27.8V
14.4V
28.8V
Table 3