Manson Engineering Industrial SBC-8112 Скачать руководство пользователя страница 4

SBC-Series Switching Mode Programmable Automatic Charger User Manual

4. OPERATIONS

4.1

Charging Methods

There are 3 charging methods.

A.

Normal Charging

1. Check and set the Dip Switch Control Settings for your battery type: Wet, Seal or AGM Type.

Then set the set the timer T to Off and PS to Off ( 

Table 3

 ).

2.

Put the ring/spade connector of your cable to the terminal pole first, then the spring washer and
screw as tight as possible.

3.

Recheck the tightness by jigging the cable and ensuring the spring washers are flat.

4.

Switch on the charger and the LED should light up in green. The charger will Boost Charge the

battery until fully charged up then the charger will switch to Float voltage automatically and the

LED will be Off.

The Charger can be left unattended without worrying about overcharging the battery. In case,

the battery becomes low again, the charger will automatically start the Boost to Float charging

cycle again.

5.

To use the Temperature Compensation Function, plug a PT100 Temperature Sensor (optional

accessory) into the Temperature Sensor Terminal and attach it firmly on the side of the battery 

FIG. 3

 ).

For 12V system( SBC-8112, 8125 ), it will regulate at -20mV/degree C increase.

For 24V system( SBC-8215 ), it will regulate at -40mV/degree C increase.

When the battery's temperature is about 60 degree C, the LED will be red and the charger will

stop charging the battery. Turn off the charger to reset the charger.

FIG. 3

 )

P.3

SBC - 8112 / 8125

 ( 12V system )

SBC - 8215

 ( 24V system )

13.9V

27.8V

14.4V

28.8V

Table 3

Содержание SBC-8112

Страница 1: ...SWITCHING MODE PROGRAMMABLE AUTOMATIC CHARGER for Lead Acid Battery SBC Series User s Manual 7673 8112 0000...

Страница 2: ...ttery is dangerous Batteries generate EXPLOSIVE gases during normal operation Provide ventilation to outdoors from the highest point of the battery compartment 5 Be extra cautious to reduce the possib...

Страница 3: ...OFF Button power on with light 2 LED INDICATOR Color Green Red LED Off Status Boost Charge Mode Over temperature Shutdown Float Charge mode TABLE 2 3 OUTPUT TERMINAL CONNECTED TO LEAD ACID BATTERY FIG...

Страница 4: ...harger will switch to Float voltage automatically and the LED will be Off The Charger can be left unattended without worrying about overcharging the battery In case the battery becomes low again the c...

Страница 5: ...will carry external loads and still keep the battery in a full charge condition without overcharging the battery When the load is On the charger will only deliver a semi boost voltage to the battery 1...

Страница 6: ...ay distance feet for 2 voltage loss 10A Max one way distance feet for 2 voltage loss 20A 14 4 5 2 12 7 3 5 10 11 5 5 5 8 18 9 6 28 5 14 5 4 45 5 22 5 2 72 5 36 1 0 115 57 5 2 0 145 72 5 4 0 230 116 Ta...

Страница 7: ...ry preset 14 8 15 5V for 12V System or 29 6 31 0V for 24V System The Temperature Sensor optional accessory protects the battery from overheating due to environment or faulty cell or low water level Wh...