Manson Engineering Industrial SBC-6108 Скачать руководство пользователя страница 9

Each of the 10 night-light mode options has a unique number of flashes. These are as follows:

Switch Setting

# of Flashes

OFF

0

2 Hours On

1

4 Hours On

2

6 Hours On

3

8 Hours On

4

10 Hours On

5

3 / OFF / 1

6

4 / OFF / 2

7

6 / OFF / 2

8

Dusk to Dawn

9

Note: Do not press the reset button when the LED is flashing during the verification

.

4.4  Temperature Sensor (Optional)

When an external temperature sensor (optional accessory) is installed, the controller will adjust
the  Bulk  and  Float  Charge  Voltage  according  to  the  temperature  of  the  battery type.  The
regulation setpoint is 25ºC. The Controller adjusts the BULK and FLOAT setpoints -0.03V/ ºC.

Only the factory provided temperature sensor (optional accessory) can be used.
If no temperature sensor is installed, the controller will set the temperature of the battery at 25ºC.

4.5  Over Temperature Protection

The operation temperature of the transistors of the PV Charge Controller is also continuously
monitored. If excessive temperature is detected, the charge controller transistors will repeatedly
and  rapidly  turn  On  and  Off  to  reduce  the  charging  rate  so  as  to  reduce  the  transistors'
temperature. In case the charging current (from the solar panel) is reduced to zero and over
temperature condition still persists, the load will also be disconnected.
When the temperature has dropped to the working range, the PV panel and the load will be
connected again.

5.  Remote Signal Terminal (Optional)

The PV controller has a remote signal output terminal (Optional) which can:
1. control the ON/OFF operation of equipment such as inverter hooked up to the battery bank to

operate along with the night-light mode program and share the safeguard function such as 
low battery disconnect and reconnect.

2. make extension connection of the battery status LED to allow remote monitoring Battery 

bank status (see Section 3.2)

Figure. 5

Table 6

P.8

Содержание SBC-6108

Страница 1: ...ype Lead Acid Battery 4 3 4 2 Select the Auto Equalization charging and Night Light Mode 4 4 PV Charge Control Mode 5 4 1 3 Stage Charge Control 5 4 2 Equalization Charging Mode Automatic or Manual 6 4 2 1 Automatic Equalization Charging 6 4 2 2 Manual Equalization Charging 6 4 3 12V DC Load Terminal Control Mode 6 4 3 1 Low Voltage Disconnect LVD 6 4 3 2 Low Voltage Reconnect LVR 6 4 3 3 Night Li...

Страница 2: ... with plastic tape or vinyl dip coating material Specifications SBC 6100 Series Models 6108 6112 6120 Battery voltage 12V Maximum PV panel open circuit voltage 26V Continuous load charge current 8A 12A 20A Maximum charge current 5 mins 10A 15A 25A Maximum load current 5 mins 10A 20A 25A Operation current no Load and no PV 30mA Voltage across terminals PV to Battery 0 6V 0 6V 0 8V Voltage across te...

Страница 3: ...age Charge Control Bulk Absorption Float to allow battery be left unattended for long period Over Temperature Protection Night Light Mode 10 selections Short Circuit Protection at load terminal Battery Reverse Polarity Protection at Battery Connection Terminal Tri Color LED indication of system and battery conditions Optional Temperature Sensor for compensated battery charging Optional Remote Sign...

Страница 4: ...arge Controller should be installed in a dry sheltered location away from sources of high temperature and moisture 3 2 LED Indicator Red Flashing Battery Voltage is lower than 12 6V Constant Red Battery Voltage has reached Low Voltage Disconnect LVD Constant Green Battery Voltage is higher than 12 6V Green Flashing Battery Voltage has reached Bulk Charging Setting Fully Charged Orange Flashing Bat...

Страница 5: ... table 5 Table 3 Preset values of the adjustable parameters 3 4 1 Bulk Voltage Setting for Sealed and Wet type Lead Acid Battery The bulk voltage of sealed gel type and wet type lead acid battery are different The preset Bulk Setpoint 14 3V is for typical Sealed Gel type Lead Acid Battery The Dip switch 3 is set to OFF position For typical Wet type Lead Acid Battery set the Dip switch 3 to ON posi...

Страница 6: ...or and PWM Pulse Width Modulation to give optimal and safe charging It makes varying On Off pulses of electrical energy from the photovoltaic PV panel in charging the battery according to the battery state It has 3 stages of charging as follows a BULK CHARGE At this mode a preset maximum constant amount of current amps is fed into the battery as no PWM is present As the battery is being charged up...

Страница 7: ...ing equalization charge it can be stopped any time by pressing the Reset button once and the controller will return to the charging mode before the Equalization charge 4 2 2 Manual Equalization Charging Set the Night Light Mode dip switch 1 to off position Press and hold the Reset button for 10seconds and the equalization charge will go on for two hour During equalization charge it can be stopped ...

Страница 8: ...ad remain turned off X Hours On Load is turned on for X hours after sunset Y OFF Z Load is turned on after for Y hours after sunset turned off during the night then turned on again Z hours before sunrise Dusk to Dawn Load is turned on all night Measure Night Length The load timer options that turn the load on again before sunrise require that the PV charge controller to measure the length of the n...

Страница 9: ... Protection The operation temperature of the transistors of the PV Charge Controller is also continuously monitored If excessive temperature is detected the charge controller transistors will repeatedly and rapidly turn On and Off to reduce the charging rate so as to reduce the transistors temperature In case the charging current from the solar panel is reduced to zero and over temperature conditi...

Страница 10: ...e Pin 6 4 Shows the battery status Red LED See Section 3 2 Pin 8 4 Shows the battery status Green LED See Section 3 2 Table 7 Pins configuration Note Pin 3 and 5 are not used in Remote Signal Terminal Rev 1 0 12 2004 7673 6112 0563 Figure 6 1 Open the case of the controller there should be a small control board near the Remote Signal Terminal as shown in figure 5 2 On the small control board there...

Отзывы: