8.2 Method B
Using two 0 – 5K Ohm variable resistors
Remark: variable resistors 5Kohm.
Remote Socket Pin Assignment for variable resistor
PIN
FUNCTIONS
REMARKS
1
Internal DC +5V
Resistor end
2
Voltage Adjust
Variable part of resistor
3
Current Adjust
Variable part of resistor
4
Ground
Another resistor end
5
Output OFF
Short to Ground
6
N.A.
7
N.A.
8
N.A.
Check the output voltage range of the power supply by adjusting the 5Kohm variable resistor.
Short circuit the main output with
10AWG
wire to check the display for CC setting by adjusting the variable resistor.
8.3 Remote Output ON/OFF Control
This remote output on/off control can be activated in any of the modes Normal, Preset, Remote and Set mode.
A. By default, Pin 5 is open and output is on.
B. Shorting Pin 5 to Pin 4 (ground) and output is off.
C. When output is off, the C.V. & C.C. LED will flash. The current output voltage and current setting will show on
the panel meter.
D. You also can adjust the output by voltage & current control knob to your desired value when output is off.
Remark: using the 8pin remote plug provided and connect with 22AWG wires.
Pin numbers are marked
on the black portion.