Manrose IVY Скачать руководство пользователя страница 4

Installation Instructions

LOCATION

• The unit must be located and installed in accordance with AS/NZS 3000 and local building codes relating to damp situations.
• This may mean that no part of the Module may be located directly above any part of a bath or shower recess or enclosure.

ght of 2 metres. At least 200mm height clearance in the ceiling cavity 

perse. The unit must also be installed at least 250mm away from walls.

• Ensure adequate air intake into the room exists through windows, vents or under the door to replace the displaced air from the 

exhaust fan.


POWER

AC220-240V ~50Hz electrical supply is required. The unit can be connected to a lighting or power circuit if loading permits. All 

electrical work must be carried out in accordance with AS/NZS 3000 or latest edition thereof, and local building codes and regulations. 

A four switch wall plate is included and must be wired as per wiring diagram supplied. Ensure the power supply is isolated before 

commencing installation. Electrical wiring must only be done by

be 

issued at completion of the installation.

Page 3 of 5

INSTALLATION

1. Use the cut out template card as a template. Place in the required 

location and mark out the hole cutting size: 523mm x 343mm. 

Before commencing cutting ensure that the area behind the intended 

location is clear of all cables, pipes and joists. Once clear, cut out the 

section along the previously marked lines.

2. Prise up the edge of fascia then take off the fascia. Remove the 

cover of the terminal and connect the wires according to the diagram. 

Connect the ducting to the unit if required.

3. Insert the unit into the ceiling cavity, ensuring the clips are resting 

against the body of the unit. Tighten the screws to ensure the unit is 

4.

located correctly.

Page 4 of 5

• Locate the heater in accordance with the requirements of the current Australian/New Zealand Wiring Rules AS/NZS 3000 relating to

damp situations.

• The heater is designed for connection to the single-phase 220-240V~ 50Hz electric mains equipped with an earth wire.

 mains at the connection point meet the single-phase 

220-240V~50Hz voltage.

• The electric mains should be equipped with an automatic circuit breaker with rated current not less than 10A.
• Switches and other controls must not be located where they can be touched by a person in the bath or shower.
• The heater must not be located immediately below a power point. Power point should not be located at the back of the heater. The

power point needs to be located outside the physical footprint of the heater to minimise heat build-up behind the heater.

• WARNING: The installation must be equipped with an all-pole disconnection mechanism with a break contact distance of at least

3mm.

ELECTRICAL WIRING 

1. 

Connect the wiring to the four-gang switch according to the below electrical diagram.

2. 

T’ functions will only operate once ‘FAN’ has been engaged.

3. 

Remove the terminal cover on the heater unit and wire according to the label adjacent to the terminal block. Make sure all cables

4. 

Turn on the power and check the switch operation.

Model No:

MRSBH

21WH / 

MRSBH

21BL

 

Rated Voltage: 220-240V~ Rated 
Frequency: 50Hz
Total Power: 2095W
Heat Wattage:Max 2000W 
Fan Power:40W
Exhaust Power:55W

IPX2

Thermostat

PTC

PTC

M

N

N

L

EXHAUST

HEAT I

HEAT II

FAN

SWITCH

L

~

M

~

CAUTION:

AN’ has been 

engaged. Please check all functions are working correctly after installation.

Page 5 of 5

CARE AND MAINTENANCE

• This fan heater must not be installed near curtains or other combustible materials.
• The appliance must under no circumstances be covered with insulation material or similar material.
• Joists, beams and rafters must not be cut or notched to install the appliance. 
• This unit must cool before cleaning. To clean the fascia, wipe with a dampened cloth. This appliance is not intended for use by 

• Ensure that this appliance is switched off from the supply mains before removing the guard.

persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they 

have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Young children 

should be supervised to ensure that they do not play with the appliance.

DISPOSAL

Do not dispose of electrical products with household waste. Please check with your local council for advice on disposal or recycling. If 

ardous substances can leak into the groundwater and get into the food 

chain, damaging your health and well-being.

Installation Instructions

Electricians, please ensure a copy of the Installation

Instructions are left with the end user for future reference

Fan Heater and Exhaust

Installation Instructions

Electricians, please ensure a copy of the Installation

Instructions are left with the end user for future reference

Fan Heater and Exhaust

Installation Instructions

Electricians, please ensure a copy of the Installation

Instructions are left with the end user for future reference

Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances.

Ivy

Premium 

Fan Heater and Exhaust

CONNECTION TO ELECTRIC MAINS

Отзывы: