![Manrose HYPER150 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/manrose/hyper150/hyper150_installation-instructions_701838002.webp)
INSTALLATION
The plastic spigots have been designed for easy mounting onto a flat solid surface such as
the top plate of a wall partition as found in a ceiling cavity or alternatively to avoid possible
resonance effects the motor can be suspended from the rafters.
Electrical Connections
NOTE:
A REGISTERED ELECTRICIAN MUST INSTALL ANY FIXED WIRING
AS PER THE NEW ZEALAND/AUSTRALIAN WIRING REGULATIONS.
BROWN
BLUE
LIVE
EARTH
NEUTRAL
GREEN/YELLOW
RED
BLACK
TIMER
FAN0372
LIVE
NEUTRAL
EARTH
LIGHT SWITCH
FLUSH BOX
(WALL MOUNTED)
BLUE
BR
OWN
GREEN/YELLO
W
YELLOW
ORANGE
IMPORTANT
•
Isolate the mains supply before making any electrical connections. This system
should be installed by a qualified electrician.
•
When fitting through an external wall, an external grille must be fitted at all times.
• Fan should only be installed by fixed wiring, a flexible cord should not be used.
• This appliance is not intended for use by persons (including children) with
reduced physical sensory or mental capabilities, or lack of experience or
knowledge, unless they have been given supervision or instruction concerning
the use of the appliance by a person responsible for their safety.
• Young children should be supervised to ensure that they do not play with the appliance.
• Precautions must be taken to avoid the back-flow of gases into the room from
the open flue of gas or other open-fire appliances when mounted in outside
windows or walls.
A
B
D
C
Product
A
B
C
D
Hyper 150
200 143 170 185
Dimension Information
0
20
40
60
80
100
120
140
0
20
40
60
80
100
120
Pressure (Pa)
Airflow (l/s)
Performance Curve - Hyper150 Fan