Manrose HYPER150 Скачать руководство пользователя страница 2

INSTALLATION

The plastic spigots have been designed for easy mounting onto a flat solid surface such as 

the top plate of a wall partition as found in a ceiling cavity or alternatively to avoid possible 

resonance effects the motor can be suspended from the rafters.

Electrical Connections

NOTE: 

A REGISTERED ELECTRICIAN MUST INSTALL ANY FIXED WIRING  

      AS PER THE NEW ZEALAND/AUSTRALIAN WIRING REGULATIONS.

BROWN

BLUE

LIVE
EARTH
NEUTRAL

GREEN/YELLOW

RED

BLACK

TIMER 

FAN0372

LIVE

NEUTRAL

EARTH

LIGHT SWITCH

FLUSH BOX
(WALL MOUNTED)

BLUE

BR

OWN

GREEN/YELLO

W

YELLOW

ORANGE

IMPORTANT  

• 

Isolate the mains supply before making any electrical connections. This system  

 

should be installed by a qualified electrician.

• 

When fitting through an external wall, an external grille must be fitted at all times. 

•  Fan should only be installed by fixed wiring, a flexible cord should not be used. 
•  This appliance is not intended for use by persons (including children) with  
 

reduced physical sensory or mental capabilities, or lack of experience or    

 

knowledge, unless they have been given supervision or instruction concerning  

 

the use of the appliance by a person responsible for their safety. 

•  Young children should be supervised to ensure that they do not play with the appliance. 
•  Precautions must be taken to avoid the back-flow of gases into the room from  
 

the open flue of gas or other open-fire appliances when mounted in outside  

 

windows or walls.

A

B

D

C

Product

A

B

C

D

Hyper 150

200 143 170 185

Dimension Information

0

20

40

60

80

100

120

140

0

20

40

60

80

100

120

Pressure (Pa)

Airflow (l/s)

Performance Curve - Hyper150 Fan

Отзывы: