background image

Installation Instructions

Specifi cations are subject to change without notice  

Page 4

[email protected] | www.manrose.co.nz 

Distributed by Simx Limited

QUIET 125mm Extraction Fan Kit

WIRING CONNECTIONS

Standard Switching

The single speed fan is switched via an existing or a new light, or auto sensor, switch 
(switch not supplied) (Fig 2).

Timer Switching

The single speed fan is switched via an existing lighting circuit switch (Fig 2) or a new ON/OFF 
switch (Fig 3) (switch not supplied), however, on the timer model, a built-in timer allows the fan to 
run on after being switched off. 

Before adjusting the timer, the mains supply must be switched OFF. When switched ON, the fan 
will operate at full speed and will continue to run at that speed, for a pre-set time, after the fan is 
switched OFF. 

1.  Remove the fan grille. The controller is factory set at 15 minutes approx. The overrun time  
 

period can be adjusted from 1-30 minutes by altering the adjuster on the control PCB. Note  

 

the exact min/max time may vary between products.

2.  To REDUCE the operating time, use a small screwdriver to turn the adjuster (Fig 4)  

 

 ANTI-CLOCKWISE.

3.  To INCREASE the operating time, use a small screwdriver to turn the adjuster (Fig 4)  

 

 CLOCKWISE.  

4.  Replace the fan grille.

Fig 2

Fig 4

Timer Adjustment

Fig 3

PUB01580 2009