INSTALLATION

INSTRUCTIONS                             

Switch off mains supply before making any electrical connections.
Installation must be supervised by a qualified electrician. 
This appliance can be used by children aged from 8 years and above 

and persons with reduced physical, sensory and mental capabilities 

or lack of experience and knowledge if they have been given 

supervision or instruction concerning the use of the appliance in a 

safe way and understand the hazards involved. 
Children shall not play with the appliance. 
Cleaning and user maintenance shall not be made by children 

without supervision.
Precautions must be taken to avoid the back-flow of gases into the 

room from the open flue of gas or other open-fire appliances when 

mounted in outside windows or walls.
Fan must be disconnected from electrical power before any 

maintenance is carried out.

CRA100HT &T
Continuous Running Axial Fans

Wiring
1. Switch off mains supply before making electrical 

connections. If in any doubt contact a qualified 
electrician.

2. These units are for fixed wiring only. A flexible cord 

must not be used. All wiring must be fixed securely 
and the cable to the fan should be a minimum of 
1mm

2

 in section. All wiring must comply with current 

I.E.E. Regulations or local regulations if outside the 
UK.

3. A double pole fused spur having contact separation 

of at least 3mm in all pole must be used and fitted 
with a 3A fuse.

4. This fan is double insulated and does not require an 

earth connection.

5. The fan should not be accessible to a person using 

either the shower or the bath. 

Location
1. When installing fan through an external wall, an 

external wall grille must be fitted at all times.

2. For best results this Extractor Fan should be fitted 

as high on the wall as possible, or if preferred, on 
the ceiling. Note: Pullcord models should not be 
installed in a ceiling.

3. Where ducted fans are used to handle moisture-

laden air, such as a bathroom, a condensation 
trap should be fitted in any vertical exhaust ducts. 
Horizontal ducts should be arranged to slope 
slightly away from the fan. Ducts passing through 
cold voids must be suitably insulated.

4. Do not install the unit within a shower cubicle 

or anywhere else where there is a risk of being 
sprayed with water (Please see our range of 
showerfans for these installations.). 

5. If the fan is installed in a room containing a fuel 

burning appliance, the installer must ensure that 
the air replacement is adequate for both the fan 
and the fuel burning appliance.