MANN+HUMMEL Industrial Filters
5
NLG
5. Maintenance/repair
Only carry out cleaning, maintenance
and repair work when the assembly is
switched off (motor, compressor, fan,
or similar). Never operate when the fil
-
ter element has been removed.
5.1 Maintenance schedule
Component
Task
Maintenance time
Main element
Replace
(if the main element cannot be
replaced, it can be cleaned if nec-
essary, as described in Section
5.2.2)
As per the operating instructions for
the respective devices or motors,
after the maintenance indica-
tor/switch has triggered or after 2
years at the latest
Secondary element
(optional)
Replace
After maintenance has been per-
formed on the main element 5
times or after 2 years at the latest
Dust discharge valve (if available)
Check for damage/function and
clean
Depending on the dust concentra-
tion in the environment (e.g. daily if
large amounts of dust)
Plastic housing
Check for damage and cracks
When performing maintenance on
the filter
Maintenance display/switch (on
clean air tube)
Check function
1)
Annually
1)
In order to attain the maximum permitted vacuum in the air intake system, reduce the size of the intake opening
slowly while the motor is running by covering it (e.g. with a piece of card or a metal plate) until the maintenance
indicator/switch triggers.
After the maintenance indicator has triggered, do
not
continue to reduce the size of the intake opening as this will
cause damage.
After the test, reset the maintenance indicator by pressing the reset button.