INTRODUCTION

THANK YOU!...
for choosing the Manley LAB SERIES STEREO 75 + 75 watt  Amplifier.  Designed by David Manley,
the Manley LAB SERIES STEREO 75 + 75 watt  Amplifier uses only the best available components,
with the shortest and cleanest signal path possible.
The circuit and the components used have been chosen carefully after years of development and
refinement for reliability, constancy and most importanly, musical, accurate, and emotional delivery of
the sound. The circuit topology is similar to other designs in the MANLEY range.  We emphasize big
beefy resevoir capacitors in the high voltage supplies giving plenty of instant energy for dynamic
performance of transient peaks and bass performance which often exceeds that of rival solid-state
amplifiers. We run high voltages on the plates of the output tubes and are thus able to run them at lower
current which will result in longer life for the output tubes.  Each output tube has its own bias adjust,
and the procedure for adjusting each tube's current draw is described in this manual.

GENERAL NOTES

LOCATION & VENTILATION
The Manley LAB SERIES STEREO 75 + 75 watt  Amplifier must be installed in a stable location with
ample ventilation.  Allow a minimum of 2 inches of clearance on the top and sides of the amplifiers,
such that a constant flow of air can flow.   Do not place amplifiers directly on high pile carpet  or any
other surface that will block the ventilation vents underneath the amplifiers. If you have small children
or pets, you should consider placing the amplifiers out of reach to prevent damage to the amplifier or
damage to your small children or pets by the amplifier as the tubes do get hot during operation.
WATER & MOISTURE
As with any electrical equipment, these amplifiers should not be used near water or moisture.

SERVICING
The user should not attempt to service the amplifier beyond that described in the owner's manual.
Refer all servicing other than biasing and tube replacement to Manley Laboratories

SPECIAL NOTES
Tubes may become loose during transit.  Straighten and press down each tube before plugging the
amplifier into the mains socket.  Furthermore, do not touch the tubes after the amplifier has been
switched on, as the tubes become very hot during operation and should only be handled after the power
has been turned off and the tubes have cooled.
Your amplifier has been factory set to the correct mains voltage for your country.  The voltage setting is
marked on the serial badge, located on the rear panel.  Check that this complies with your local supply.

Thank you again, and please enjoy!

Содержание LAB STEREO 75+75

Страница 1: ...MANLEY LABORATORIES INC MANLEY LABORATORIES INC 13880 MAGNOLIA AVE CHINO CA 91710 TEL 909 627 4256 FAX 909 628 2482 OWNER SMANUAL MANLEY LAB SERIES STEREO 75 75 WATT AMPLIFIER...

Страница 2: ...DUCTION 3 MAINS CONNECTIONS 4 CONNECTING YOUR AMPLIFIER 5 DIAGRAM TOP VIEW 6 DIAGRAM REAR VIEW FRONT VIEW 7 BIAS PROCEDURES 8 OPERATIONAL NOTES 9 SPECIFICATIONS 10 WARRANTY 11 WARRANTY REGISTRATION 12...

Страница 3: ...ion Allow a minimum of 2 inches of clearance on the top and sides of the amplifiers such that a constant flow of air can flow Do not place amplifiers directly on high pile carpet or any other surface...

Страница 4: ...s of the wires in the mains lead may not correspond with the coloured marking identifying the terminals in your plug proceed as follows The wire which is coloured GREEN YELLOW must be connected to the...

Страница 5: ...cable to the black binding post Ensure that the other end of the cable is connected correctly to the speaker Tighten the binding posts by hand If you use a nut driver 3 8 do not over tighten the post...

Страница 6: ...your warranty DRIVER TUBES 2 x 6414 The 6414 is an American military uprated version of the 12BH7A with increased current drive INPUT TUBE 12AT7WA The 12AT7WA has several equivalent numbers 12AT7 12A...

Страница 7: ...E 120V 5A 240V 3A SLO BLO MAINS IN IEC MANLEY LABORATORIES INC LAB SERIES 75 WATT STEREO DESIGNED BY DAVID MANLEY FRONT VIEW RIGHT SPEAKER OUTPUT BINDING POSTS REAR VIEW LEFT SPEAKER OUTPUT BINDING PO...

Страница 8: ...input either leave the preamplifier or source signal turned off or unplug the amplifier input Also leave your loudspeakers connected as these provide an ideal load on the output DO NOT EVER OPERATE YO...

Страница 9: ...USES The fuses used in your amplifier are standard 1 4 x 1 1 4 SLO BLO types The correctly rated fuse has been installed at the factory for your country s voltage If replacing a fuse always unplug the...

Страница 10: ...10 Hz 30 KHz Input Sensitivity 800 mV Input Impedance 100 KOhm Load Impedance 5 Ohm fixed S N Ratio 75W 80 dB Power Consumption 120 Watts Quiescent 540 Watts Both channels driven to full power Mains...

Страница 11: ...rwarrantyregistrationcard IfaManleyLaboratories productfailstomeettheabovewarranty thenthepurchaser ssole remedyshallbetoreturntheproducttoManleyLaboratories wherethedefectwillberepaired withoutcharge...

Страница 12: ...o ______________________ PURCHASE DATE ______________ SUPPLIER ______________________ PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES MODEL MANLEY LAB SERIES STEREO 75 75 SERIAL No _____...