BIAS PROCEDURES

The Manley Euro Stereo 100 is a fixed bias system that requires very little attention.  If you wish
to adjust or check the bias, follow the following steps.

1.

On diagram 2, which depicts the top panel of the amplifier, you can see 4 black tip jacks

and 1 green tip jack.  To measure the current draw of each output tube place the positive probe
(red) into the black tip jack for the tube you wish to measure and the negative probe (black) in
the green (GROUND) tip jack and set the meter to read 'millivolts'.

2.

Each of the four (4) output tubes can have its own bias adjusted by altering its own bias

adjust pot.  On diagram 2, you can see the numbering sequence for the 4 output tubes, the
corresponding tip jack (measurement point) and bias adjust pot.

3.

The first step to setting the bias is to turn on the amplifier and ensure that there is zero

signal input.  Also, leave your loadspeakers connected as these provide an ideal load on the
output.  It is recommended that you leave the amplifier on long enough to ensure that the tubes
have reached their stable current draw.

5.

Place the probes in the first black tip jack (negative probes remains in the green tip jack

for whole biasing proceedure) and adjust the first bias trip pot (see diagram 2) until you measure
300 to 350 mV.  Since you are measuring across a 10 ohm cathode resistor, this would
correspond to a 30 to 35 mA bias current.

6.

If you are unable to bring the bias voltage down to 300 to 350 mV on any tube then we

recommend that the tube be carefully watched or replaced.

7.

Follow step five with the remaining tubes.  Once they are all set, your amplifier should

be in perfect operation.

Whenever replacing an output tube, or when retubing the unit, use

tubes of the same type and quality as was fit by the factory. Watch and adjust the bias for the
specific output tube or tubes you are replacing as soon as you turn on the amplifier, then check
again after a half hour, and again in a few hours. Should you have any questions, or wish to
purchase approved tubes from us here at Manley Labs, please do not hestitate to call.

Содержание 100 WATT STEREO AMPLIFIER

Страница 1: ...MANLEY LABORATORIES INC OWNER SMANUAL MANLEY 100 WATT STEREO AMPLIFIER MANLEY LABORATORIES INC 13880 MAGNOLIA AVE CHINO CA 91710 TEL 909 627 4256 FAX 909 628 2482 ...

Страница 2: ...CONTENTS INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTINGYOURAMPLIFIER 5 BIAS PROCEDURES 6 OPERATIONAL NOTES 7 SPECIFICATIONS 8 WARRANTY 9 WARRANTY REGISTRATION 10 SECTION PAGE ...

Страница 3: ...ost speakers Other output impedances can be achieved by changing the configuration of the transformer secondary Please contact us at the factory should you need to do this Thank you again and please enjoy GENERAL NOTES LOCATION VENTILATION The Manley Stereo 100 Amplifier must be installed in a stable location with ample ventilation Allow a minimum of 2 inches of clearance on the top and sides of t...

Страница 4: ...NEUTRAL terminal BROWN LIVE terminal As the colours of the wires in the mains lead may not correspond with the coloured marking identifying the terminals in your plug proceed as follows The wire which is coloured GREEN YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or coloured GREEN or GREEN and YELLOW The wire which is coloured B...

Страница 5: ... cable to the black binding post See diagarm 2 Ensure that the other end of the cable is connected correctly to the speaker Tighten the binding posts by hand If you use a nut driver 3 8 do not over tighten the posts or you may breaak the connection inside the amplifier 4 Ensure that the mains switch on the front panel is in the off or 0 position 5 Turn on Preamplifier and any source components you...

Страница 6: ... output It is recommended that you leave the amplifier on long enough to ensure that the tubes have reached their stable current draw 5 Place the probes in the first black tip jack negative probes remains in the green tip jack for whole biasing proceedure and adjust the first bias trip pot see diagram 2 until you measure 300 to 350 mV Since you are measuring across a 10 ohm cathode resistor this w...

Страница 7: ...e recommend that you have your amplifier checked every 3 4 years depending on usage usually the amplifier will require re tubing after this time has elapsed PANEL LAMP The lamp which illuminates the front panel insert is easily replacable should it ever burn out To replace it use only the same type with the same or greater voltage rating In these amplifiers the lamp is a FUSE LAMP STYLE 8V 0 15mA ...

Страница 8: ...into 5 ohms Frequency Response 5 dB 10 Hz 35 KHz Input Sensitivity 800 mV Input Impedance 100 KOhm Load Impedance 5 Ohm S N Ratio 350W 80 dB Power Consumption 220 Watts Quiescent 420 Watts Full Power Mains Fuse 100 110 120V 6 A Slo Blo 220 240 V 3 A Slo Blo B Fuse 1A Dimensions W 19 D 13 H 7 inches Weight 46 lbs ...

Страница 9: ...urwarrantyregistrationcard IfaManleyLaboratories productfailstomeettheabovewarranty thenthepurchaser ssole remedyshallbetoreturntheproducttoManleyLaboratories wherethedefectwillberepaired withoutchargeforpartsandlabour Theproductwillthenbereturnedviaprepaid insuredfreight methodandcarriertobedeterminedsolelybyManleyLaboratories Allreturnstothefactorymust beintheoriginalpacking newpackingwillbesupp...

Страница 10: ..._ SERIAL No ______________________ PURCHASE DATE ______________ SUPPLIER ______________________ PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES MODEL ____________________ SERIAL No ______________________ PURCHASE DATE ______________ SUPPLIER _______________________ NAME OF OWNER _______________________________________________ ADDRESS __________________________________________________...

Отзывы: