background image

16.08.2013     

2

 

MANKAR HQ

 

 
Noise emission from the unit equates to less than 70 dB (A). 

 

Protective measures

 

Observe remarks in the usage instructions for the 
pesticide regarding the safety of the user; wear 
recommended body protection. Wear protective gloves 
when filling the chemical. 
Do not eat, smoke or drink while working with 
pesticides. 
Avoid chemical spillage without fail. After completion of the 
work, thoroughly clean hands and face. 
Thoroughly clean and dry the unit immediately following its 
usage. Never use the mouth to blow out nozzles or other 
small parts! 
 

Keep pesticides and applicators away from children. 

 

Assembly and preparation for the first application 

Assembly of this unit is described on page 3. 
Before the first application of the unit, allow the battery to charge for at least 8 hours. First plug the applicator plug into the 
loading socket, then plug the charging device into the 230 V power outlet. After ca. 8 hours charging time, the battery has 
reached its full voltage capacity. When the charging process is complete, first unplug the charging device from the 230 V 
power outlet, then unplug the unit plug from the charger socket. 
The spray width should be subsequently checked - ideally with a piece of cardboard laid out on the ground - and the flow 
rate adjusted. If the unit is switched on the battery monitoring LED lights green (fig. page 3/4) 
 
Before using the MANKAR HQ the breather hole of the lid has to be opened. 
If the air-vent is closed there won’t be an even chemical flow. 
After usage the breather hole has to be closed to prevent leaking. 
 
 

General remarks about the function and regarding the application of the unit 
 
Pesticides:

  This applicator was originally designed for the undiluted application of Roundup products (Glyphosate). 

Practical experience has shown, however, that other herbicides can also be deployed in conjunction with this technology. 
Considering the many products on the market with their differing formulations, it is not possible to provide a complete list 
with application rate recommendations. The specifications depicted below for adjusting the applicator relate to the usage of 
Roundup UltraMax (Glyphosate 450 gr/ltr). In general, all products with a comparable viscosity are suitable. If you intend to 
use a product other than Roundup UltraMax, its application should be initially tested on a trial basis over a small area. In 
any case, the usage instructions for the chosen herbicide should be observed along with the local requirements. 
Because of the compatibility with the materials used never use aggressive, solvents containing cleaning agents or gasoline. 
 
 

Applicator function: 

The rotating atomiser is driven by means of a rechargeable battery. Metering takes place by means of 

a metering valve. Droplets are formed by the centrifugal force of the rotating atomiser. The droplets are discharged 
downwards by the rotating atomiser through a step-free, adjustable segment. The residual chemical in the tank, not able to 
be applied, is approximately 10 ml. This residual fluid can be refilled back into the original herbicide container. 
 

Checking applicator function: 

Chemicals can flow at differing rates, more quickly or slowly, due to temperature variations. 

For this reason, the flow rate depicted in the metering table must be checked and corrected as necessary. This technology 
is not suitable for the application of water. Always use herbicides for testing the spray process and for calibrating the flow 
rate. Check the rotating atomiser for cleanliness and free turning movement on a daily basis. Check the application volume 
from time to time throughout the season. 
 

Deployment of the applicator:

 Position the spray hood directly above the ground - if the spray hood is held too high, the 

danger of spray driftage exists. During operation, chemical fluid will collect in the atomiser reservoir and can continue to drip 
for few seconds after pressing the switch-  valve  unit.  Make sure that the valve of the bottle lit is open before use. After 
usage close the valve again to provide leakage. 

 
Attention!  
If there is any leakage the stop working and repair the unit. 

Before lifting or tilting the spray hood, it is essential that the stop valve is closed and the atomiser motor is switched off. 
 

Cleaning:

 It is common practice that spraying systems need a minimum of service and maintenance same applies for the 

MANKAR HQ. Rinse the unit with warm clear water. To accelerate the cleaning procedure a cleaning agent like “tank-
cleaner” can be used. Regular cleaning reduces sediments and prevents obstructions of the valve and blocking of the 
atomizer. 

1=   open 
0= closed 

 Draft of the bottle lid 

Содержание HQ 30

Страница 1: ...agency Application is to be performed only by a competent user Remarks about usage of the unit Settings This system is not suitable for the application of water Use herbicides for testing the spray a...

Страница 2: ...scosity are suitable If you intend to use a product other than Roundup UltraMax its application should be initially tested on a trial basis over a small area In any case the usage instructions for the...

Страница 3: ...PowerFlex applied Pre position Droplets per ml per applied Pre position Droplets per ml per quantity desired metering knob minute minute quantity desired metering knob minute minute 1l ha A 50 2 0 1l...

Страница 4: ...sired volume can be regulated at the metering valve by setting a greater or lesser flow rate Spray width Hold the applicator in its working position above the overlay e g cardboard or paper Actuate th...

Страница 5: ...charge The applicator can be used for ca 8 hours with a fully charged battery Battery and motor monitoring If the battery is fully charged the LED lights green If the battery was charged for 8 hours...

Страница 6: ...width from 2007 without atomiser and spray hood bracket 102965 Screw kit MANKAR HQ 102445 Charger 100 240 6V DC 450mA NEW no pic Item Part No Description Item Part No Description 103150 Atomiser for M...

Страница 7: ...le Tank cleaner and mount it 3 Set the Dosing valve to the max water tap symbol 4 Switch the unit on switch on hand grip let it run for app 3 minutes 5 Charge the MANKAR HQ with the attached charger 6...

Страница 8: ...le responsibility that the following products are in conformity with the provisions of the following Council Directive 2006 42 EG Typ MANKAR HQ with 0 5 l reservoir MANKAR HQ with 1 l bottle Hiske Wei...

Отзывы: