Location of Condensing Unit
³
The air temperature must be at least -20°F (-28.9°C) but must
not exceed 130°F (54.4°C).
³
CVD675/CVD1185/CVD2075 Only
- The air temperature must
be at least -20°F (-28.9°C) but must not exceed 120°F (48.9°C).
³
CVD1486 Only
- The air temperature must be at least 50°F
(10°C) but must not exceed 110°F (43°C).
³
The location must not allow exhaust fan heat and/or grease to
enter the condenser.
³
The location must not obstruct airflow through or around the
condensing unit.
Содержание S model
Страница 1: ...S Model QuietQube Ice Machines with CVD Technology Installation Training ...
Страница 3: ...Typical QuietQube System Installation ...
Страница 11: ...CVD Rise Drop Verify the Condensing Unit and Ice Machine Head Section are within the guidelines ...
Страница 16: ...Inspection Remove carton inspect ice machine and condensing unit for shipping damage ...
Страница 19: ...Model Serial Number Location Back of Ice Machine Inside of Ice Machine ...
Страница 21: ...Warranty Registration Website Warranty Registration Form ...
Страница 22: ...Level Bin Thread leveling leg into base of bin Level the bin to assure the bin door closes and seals properly ...
Страница 23: ... Place the ice machine on top of the bin Make sure ice machine is flush with the sides of the bin Mount on Bin ...
Страница 24: ...Ice Machine Wiring Install strain relief and proper wiring to ice machine head section ...
Страница 29: ...Potable Water Supply Water Installation without filter Install union and shut off valve ...
Страница 32: ...Lift Unit Trained qualified personnel are required for rigging and lifting ...
Страница 41: ...Secure Line Set Secure Line Set as Needed Do not crush compress insulation ...
Страница 49: ...Final Set Up ...
Страница 50: ...Installation Checklist Complete the installation checklist in the Installation Use Care Manual ...
Страница 51: ...Complete Installation Sanitize the Ice Machine Energize Verify Water Level Run 2 Freeze Cycles ...
Страница 52: ...S Model QuietQube Ice Machines with CVD Technology Installation Quiz Click Here to Launch ...