15
G. Remove the Water Trough
•
Apply downward pressure on the siphon tube and
remove from the bottom of the water trough.
•
Remove the upper thumbscrew.
•
While supporting the water trough remove the two
thumbscrews from beneath the water trough.
•
Remove the water trough from the bin area.
H. Remove the ice damper.
•
Grasp ice damper and apply pressure toward the left
hand mounting bracket.
•
Apply pressure to the right hand mounting bracket
with thumb.
•
Pull ice damper forward when the right hand ice
damper pin disengages.
Installation
•
Place ice damper pin in left hand mounting bracket
and apply pressure toward the left hand mounting
bracket.
•
Apply pressure to the right hand mounting bracket
with thumb.
•
Push ice damper toward evaporator until right hand
damper pin engages.