70
3. To re-install into ice machine, grasp one end of
the water shutters, install one end, pivot the
opposite end and pull down into position. Make
sure tabs are secure in grooves.
To remove water shutter assembly:
Removing the water shutters while the water
pump is running will allow water to spray from ice
machine. Disconnect the electrical power to the
ice machine at the electric service switch box and
turn off the water supply.
1. Slide evaporator bucket forward 1/2" (13 mm).
2. Lift shutter assembly straight up.
!
Warning
GRASP
WATER
SHUTTERS
HERE
WATER
SHUTTERS
SHUTTER
ASSEMBLY