44
Part Number 020007115 06/27/2019
Controls
Section 6
CLEANING MODE
• Press and hold the Prime/Clean button until the LED
around the button turns on to place the unit into
cleaning mode.
• Cleaning button will illuminate blue in color around the
button indicating unit is in cleaning mode.
Abort Cleaning Mode
• To abort cleaning mode press and hold the cleaning
button until the LED around the Prime/Clean button
turns OFF.
NOTE: This exits cleaning mode into keg change mode and
LED will no longer be illuminated. Priming is required after
aborting cleaning or clearing an error.
See “Priming the System” on
page 43
Immortant
If cleaning mode is accidentally aborted or aborted because
of an issue/reason, then the cleaning process will need to
start over from the beginning after a two (2) minute wait.
For an overview on cleaning “Daily & Weekly Cleaning” on
page 31. For step by step cleaning please refer to the
manual that ships with the unit, part number 9290312
ERROR CODE
The Prime/Clean Button LED will blink ON/OFF rapidly
indicating unit is in an error state.
NOTE: Error mode can be caused by the following;
A. Keg Needs Primed or Failed to Prime
B. Keg is Empty
Clearing Error Code
To exit error state;
• Close both taps if open
• Press and hold the Prime/Clean button until the LED
around the button turns OFF.
This clears the error state and exits into keg change mode.
NOTE: Priming is required after aborting cleaning or clearing an
error.
See “Priming the System” on page 43.
Once an error state
is cleared the cleaning process can be started over after a two (2)
minute wait.
Refrigerated Cabinet
CONTROLS/PROGRAMMING/SETTINGS
After the unit is connected to power it will automatically
begin operating. With the doors closed, the temperature of
the cabinet should reach 36°F to 40°F (2°C to 4°C) in about
one hour.
A thermostat located in the evaporator housing on interior
rear of the unit, controls the temperature in the unit. The
factory setting for the control is 4 and maintains about 38°F
(3°C) in the box. Set toward 1 for higher temperatures and
toward 7 for lower temperatures.
Refrigerators defrost automatically with every cycle of the
compressor. The water generated is routed to a pan on the
rear of the unit and is evaporated by the heat given off by
the compressor.
NOTE: During normal operation the evaporator fan runs
continuously.
Содержание Multiplex N2Fusion
Страница 4: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...14 Part Number 020007115 06 27 2019 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 34: ...34 Part Number 020007115 06 27 2019 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 54: ...54 Part Number 020007115 06 27 2019 Charts Section 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 56: ...56 Part Number 020007115 06 27 2019 Diagrams Section 9 PLUMBING DIAGRAM NITROGEN COFFEE NITRO COFFEE ...
Страница 62: ...62 Part Number 020007115 06 27 2019 Diagrams Section 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 63: ......