D. Install the MINI
1. Select a Location for the MINI
a. For safe and efficient operation, observe the following criteria when selecting an
operating location for a MINI
b. Transport the MINI on its pallet.
c. Passages and doors must be high enough and wide enough for a MINI and its pallet. See
Table 2-1.
d. Location selected must be capable of supporting a MINI. See Table 2-1.
e. The area MUST be free from and clear of combustible materials.
f.
KEEP THE MINI AREA FREE AND CLEAR FROM COMBUSTIBLES.
g. Level the floor if needed.
h. The operating surface must be level enough to allow leveling a MINI with its adjustable
legs, or those provided with the appropriate Cleveland Range provided stand.
i.
A MINI MUST be level both front to back and side to side.
j.
Position the MINI so it will not tip or slide.
k. The ambient temperature should be within 40° and 95° F.
l.
Proper air supply for ventilation is REQUIRED for and CRITICAL to safe, efficient
operation of a MINI.
m. Operating Clearances: Sides and Rear - 3".
n. Service
Clearance: Above - 20”.
o. Allow for sufficient distance if a "high heat source" (e.g. broiler) is located next to the unit
p. Allow for sufficient clearance on left side for service access. Contact Cleveland Range at
216-481-4900 for recommendations.
q. Allow extra clearance on the side if the appliance has the optional hand shower.
r. Installation must comply with all local fire and health codes.
s. Do not install the MINI directly over a drain. Steam rising up out of the drain will adversely
affect operation, hamper cooling air circulation, and damage electrical and electronic
components.
t.
Do not obstruct the flow of ventilation air. Make sure the air vents of the MINI are not blocked.
TABLE 2-1 WEIGHT AND DIMENSIONS INCLUDING PALLET AND CRATE*
The MINI
MODEL
WEIGHT WIDTH DEPTH
HEIGHT
6.08 143
lb
22.84”
32.65”
31.5”
3.10 190
lb 25.6” 36.5” 32.1”
6.10 190
lb 25.6” 36.5” 32.1”
10.10
215
lb 22.84” 35.83” 41.93”
6.10 2in1
310 lb
22.84”
36.81”
67.38”
2. Exhaust Hood Requirements
a. Install the MINI under an Exhaust Hood.
b. The exhaust hood must extend over the exhaust ports and meet the following requirements:
1) The Exhaust hood must be sized for the cumulative ventilation requirements of all the
appliances in the area under the hood, including the MINI.
2) If an existing hood cannot be used, a new one must be constructed over the MINI.
3) When determining hood size; include Operating Clearances of 3 inches sides and
rear, and Service Clearance of 20 inches overhead. See Table 2-2