background image

 

 

                      K00177 

                                             IB-0620/0820/1020 
                ON A CORNELIUS ABS OR ED150 ICE DISPENSER 

                                                            Installation Instructions 

 
 

1.

 

Set adapter on top of the dispenser.  Be sure to position the adapter with the backside flange tight to the dispenser. 

2.

 

Using the slotted holes in the adapter as a template, drill four (4) 9/64” diameter holes at the bottom of the slots.  
NOTE:  Do not drill deeper than 1/4” past the sheet metal.  Use a drill stop! 

3.

 

Fasten adapter to dispenser using the four (4) #8 screws supplied with the adapter kit. 

4.

 

Set the ice machine on top of the adapter.  Align holes in ice machine front angle with the rivnuts on the adapter. 

5.

 

Secure the ice machine to the adapter with two (2) #8-32 thumbscrews supplied with the ice machine. 

6.

 

Set the front bin cover onto the dispenser.  The back flange of the bin cover will latch onto the adapter. 

7.

 

Rotate retaining arms into position, as shown for normal ice machine operation. 

 
 

 
 

 
Manitowoc Ice, Inc.                                                                                                                                                            

2110 South 26 Street, P.O. Box 1720, Manitowoc, WI  54221-1720 USA                                                                                                   

#8-32 Thumbscrew 
 2 Places 

Cornelius ABS or ED150 
            Dispenser

 

#8 Screw  
4 Places 

RH Retaining Arm 

Bin Cover 

Adapter 

LH Retaining Arm 