17
Installation and Service Manual
5001192
Revision 03 February, 2003
COUNTER TOP INSTALLATION
If beverage valves are supplied with your dispenser, con-
nect them to the beverage system at this time according
to the information supplied by the beverage supplier.
Route the electric wires under the dispenser and out to
the electrical receptacle.
Replace the drain pan to the dispenser. Secure the free
ends of the vinyl drain tubing to the drain connections
supplied by the owner/operator. Attach the splash panel
to the front of the dispenser.
Clean and sanitize the dispenser according to the
directions in this manual.
Drain
3/4" FPT
Cord
FLOOR INSTALLATION
(H265 Series Dispenser)
Check the equipment location. Assure the proper drain
and electrical requirements are available before proceed-
ing. Carefully remove the dispenser from the shipping
carton. Lay the dispenser on its’ back. Use the shipping
cardboard as a protective interface between the dis-
penser and the floor. Thread the legs into the leg gus-
sets on the bottom corners of the dispenser.
Carefully pick up the dispenser, setting it in place. Be
sure the dispenser is stable and is level. Place a level
on the top of the bin, side to side and front to back to see
if the bin is level. Adjust the bin legs to level the dis-
penser.