![Manitowoc Grove GRT9165 Скачать руководство пользователя страница 242](http://html.mh-extra.com/html/manitowoc/grove-grt9165/grove-grt9165_service-manual_701207242.webp)
UNDERCARRIAGE
GRT9165 SERVICE MANUAL
8-28
Published 10-01-2020 Control # 699-00
Outrigger Extension Cylinder
Description
Two outrigger extension cylinders(1, Figure 8-28) are utilized
within each outrigger box assembly. The extension cylinders
provide the force for the outrigger beam’s horizontal
movement. The cylinder weighs approximately 54 kg
(119 lb).
Removal
1.
Remove the outrigger extension beam (1, Figure 8-28)
from the outrigger box. For more information, see
2.
Remove the cotter pin (2) and clevis pin (3) securing the
rod end of the extension cylinder (1) to the outrigger
beam (8).
3.
Pull the extension cylinder (1) from the outrigger beam
until the hydraulic hoses (4) on the rod end of the
cylinder can be accessed. Tag and disconnect the
hydraulic hoses (4) from the rod end of the cylinder. Cap
or plug all openings.
4.
Remove the extension cylinder (1).
5.
If necessary, remove capscrews (5), locknuts (6), and
wear pads (7) from the extension cylinder (1).
Installation
1.
If necessary, install the wear pads (7) on the extension
cylinder (1) with capscrews (5) and locknuts (6).
2.
Place the extension cylinder (1) in the beam.
3.
Position the extension cylinder (1) so the hydraulic ports
on the rod end of the cylinder can be accessed. Connect
the hydraulic hoses (4) to the ports as tagged during
removal.
4.
Push the extension cylinder (1) into the outrigger beam.
Align the cylinder rod with the clevis in the beam. Apply
anti-seeze to the clevis pin (2) and secure in place with
the clevis pin (2) and cotter pin (3).
5.
Install the outrigger beam (8) in the outrigger box. For
more information, see
Functional Check
1.
Activate the hydraulic system. Fully extend and retract
the outrigger.
2.
Observe the operation of the outrigger beam. If hydraulic
lines are reversed, stop immediately and connect lines
properly per instructions. Verify jack cylinder hoses are
not trapped or twisted by full outrigger beam retraction. If
any hose is trapped, stop immediately and install lines
properly to avoid trapping.
3.
Check the hydraulic connections and hoses for any
evidence of leakage. Make repairs as needed.
4.
Recalibrate the Outrigger Monitoring System in the
ODM as needed.
FIGURE 8-28
2
3
8
4
5
6
1
Outrigger Extension Cylinder
2
Clevis Pin
3
Cotter Pin
4
Hydraulic Hose
7
5
Capscrew M8x25 8.8
6
Locknut
7
Wear Pad
8
Outrigger Beam Assembly
1
10232
Содержание Grove GRT9165
Страница 1: ...Service Manual Grove GRT9165 9897 ...
Страница 4: ...THIS PAGE BLANK ...
Страница 112: ...HYDRAULIC SYSTEM GRT9165 SERVICE MANUAL 2 70 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 138: ...ELECTRICAL SYSTEM GRT9165 SERVICE MANUAL 3 26 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 296: ...MAINTENANCE AND LUBRICATION GRT9165 SERVICE MANUAL 9 52 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 301: ......
Страница 302: ......