![Manitowoc Grove GRT880 Скачать руководство пользователя страница 193](http://html.mh-extra.com/html/manitowoc/grove-grt880/grove-grt880_operators-manual_701204193.webp)
Grove
Published 3-25-2020, Control # 643-04
5-27
GRT880 OPERATOR MANUAL
MAINTENANCE AND LUBRICATION
5
Hydraulic
Item
Lube Point
Description
Figure No.
Approved
Lubricant
Lube
Capacity
Lube Interval
Application
110
Hydraulic Tank
(Tank Only)
J
894 L
(944.6 gal)
(tank only)
Check fluid level every
10 hours or daily.
• Use sight gauge on
side of tank, with
boom down and all
outrigger cylinders
retracted.
• Drain and refill as
necessary
NOTE:
•
Environmental and other conditions can dramatically affect the condition of hydraulic oil and filters. Therefore,
specific intervals for servicing/changing hydraulic oil, filters and hydraulic tank breathers cannot be set.
However, it is imperative for the continued satisfactory performance of Grove cranes that inspections be
performed on the basis of how and where each crane is used. Airborne and ingested contaminants can
significantly reduce the life of oil and condition of hydraulic oil filters and tank breathers.
•
Under normal operating conditions, it is recommended that hydraulic oil, filters and breathers be inspected
and oils sampled at least every 3 to 6 months and more frequently for severe operating conditions.
Inspections should be for airborne and/or ingested particles and water that deteriorate and contaminate the
oil (e.g., oil appears “milky” or no longer has a transparent clear to amber color). The return filter by-pass
indicator should be observed daily to determine if the contaminants content may be high. If indicator reaches
red zone or indicates a by-pass condition, hydraulic oil must be sampled. The hydraulic tank breather should
also be inspected to ensure it does not restrict air flow in and out of the reservoir.
•
To inspect hydraulic oil, fill a small glass container with a sample of reservoir oil and another glass container
with fresh oil. Let samples stand undisturbed for one to two hours, then compare the samples. If reservoir oil
is heavily contaminated with water, the sample will appear “milky” with only a small layer of transparent oil on
top. If the “milky” appearance was due to air foaming, it will dissipate and the oil should closely match the
fresh oil. Should you have any questions, please contact your local authorized Grove distributor.
•
Hydraulic oil shall meet or exceed ISO 4406 class 17/14 cleanliness level.
111
Hydraulic Filter
---
---
Change filter element
when indicator is red.
Oil must be at operating
temperature.
FIGURE 5-16
8617
FRONT
110
110
111
Содержание Grove GRT880
Страница 1: ...Operator Manual Grove GRT880 8968 ...
Страница 4: ...THIS PAGE BLANK ...
Страница 10: ...TABLE OF CONTENTS GRT880 TOC 6 THIS PAGE BLANK ...
Страница 16: ...INTRODUCTION GRT880 OPERATOR MANUAL 1 6 Published 3 25 2020 Control 643 04 THIS PAGE BLANK ...
Страница 54: ...SAFETY INFORMATION GRT880 OPERATOR MANUAL 2 38 Published 3 25 2020 Control 643 04 8496 3 FIGURE 2 10 ...
Страница 166: ...SET UP AND INSTALLATION GRT880 OPERATOR MANUAL 4 24 Published 3 25 2020 Control 643 04 THIS PAGE BLANK ...
Страница 198: ...5 32 Published 3 25 2020 Control 643 04 MAINTENANCE AND LUBRICATION GRT880 OPERATOR MANUAL THIS PAGE BLANK ...
Страница 200: ...OPERATOR MANUAL GRT880 6 2 THIS PAGE BLANK ...
Страница 201: ......
Страница 202: ......