Component Disassembly for Cleaning/Sanitizing
The ice machine must be disassembled cleaned and sanitized
every six months.
,
Caution
Do not mix Cleaner and Sanitizer solutions together. It
is a violation of Federal law to use these solutions in a
manner inconsistent with their labeling.
1. Turn off water supply to ice machine.
n
Warning
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or Sanitizer.
2. Place toggle switch in the CLEAN position for 30 seconds
to drain water from reservoir, then move toggle switch
to OFF position.
3. Run dispenser to transfer all ice from the bin to a
container.
n
Warning
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
4. Disconnect electrical power to the ice machine.
5. Remove top cover.
A. Remove two thumbscrews.
B. Lift up on top cover to remove.
Remove
Screws
6. Remove front cover.
A. Lift up on front cover.
B. Pull forward to disengage keyhole slots.
7. Remove ice chute cover.
A. Turn the two thumbscrews 1/4 turn.
B. Lift to remove cover.
Loosen
Thumbscrews