![Manitowoc 2250 MAX-ER 2000 Скачать руководство пользователя страница 156](http://html.mh-extra.com/html/manitowoc/2250-max-er-2000/2250-max-er-2000_operators-manual_701156156.webp)
Reference
Only
SET-UP AND INSTALLATION
2250 MAX-ER 2000 OPERATOR’S MANUAL
4-76
Published 01-08-13, Control # 049-05
Anchoring Wire Rope to Button Socket
See Figure 4-41 for following procedure.
1.
Remove pin from socket.
2.
Install button end of load line in socket.
3.
Pin socket to anchor point.
4.
Securely tighten locking screw.
PAD EYE USAGE FOR WIRE ROPE
REEVING
See Figure 4-42 for following procedure.
General
Some rotation-resistant wire rope supplied by Manitowoc is
equipped with a No. 1.5 pad eye welded to the leading end of
the wire rope.
A sucker-line can be attached to the pad eye to make it
easier to reeve the load block.
Safety
1.
For No. 1.5 pad eye, do not exceed 1,000 lb (4,45 kN)
single line pull.
2.
Make sure sucker line and rope clips are rated for at
least 1,000 lb (4,45 kN) line pull.
3.
Inspect pad eye prior to each use. Replace it if:
•
Any original dimensions have changed .
•
Cracks or breaks exist in metal or weld.
Button Socket Assembly
Load
Line
A1263
Button
Button
Socket
FIGURE 4-41
Pin
Locking
Screw
(behind)
WARNING
Flying Part Hazard!
Pad eye on end of wire rope has been provided for
reeving purposes only. Any other use is neither
intended nor approved.
Pad eye can break and fly apart with considerable force if
it is overloaded, not used properly, or not maintained
properly.
Содержание 2250 MAX-ER 2000
Страница 1: ...R e f e r e n c e O n l y MAX ER 2000 Operator Manual Manitowoc 2250 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y ...
Страница 56: ...R e f e r e n c e O n l y 2250 MAX ER 2000 OPERATOR S MANUAL 3 ii Published 01 08 13 Control 049 05 ...
Страница 195: ...R e f e r e n c e O n l y ...
Страница 196: ...R e f e r e n c e O n l y ...