Reference
Only
18000 SERIVCE/MAINTENANCE MANUAL
HYDRAULIC SYSTEM
Manitowoc
Published 12-05-17, Control # 035-23
2-39
2
Pump or Motor Override
for the following procedure.
1.
Start and run engine at low idle.
2.
Rotate manual override (2) in either direction to stroke
pump or motor in corresponding direction.
3.
If pump or motor is operating properly, corresponding
side of circuit will stall.
Solenoid Valve Override
1.
Start and run engine at low idle.
2.
Insert a rigid steel rod through hole in end of valve cap.
3.
Depress valve spool with rod.
4.
If valve is operating properly, corresponding side of
circuit should operate.
DANGER
Falling or Moving Load Hazard!
To prevent unexpected movement of loads or crane when
operating any manual override:
•
Park crane in an area where it will not interfere with
other job site equipment or structures.
•
Land all loads and lower boom onto blocking at
ground level.
•
Park all crane functions.
Item
Description
Item
Description
1
Pump EDC/Motor PCP
4
Solenoid Valve
2
Manual Override
5
Manual Override (though end cap)
3
Electrical (DIN) Connector
FIGURE 2-32
1
P96
6a
3
Typical Pump Installation
2
Typical Solenoid Valve Installation
P19
92
4
3
5
Содержание 18000
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Страница 315: ...R e f e r e n c e O n l y ...
Страница 316: ...R e f e r e n c e O n l y ...