2.4 CF3 Module Signals
This section describes how CF3 module signals connect to the platform hardware components (described in
Hardware Component Connections on page 11
).
Important:
CF3 module signal availability depends on the module type—some modules may not implement certain
Extension signals from the CF3 specification.
2.4.1 ADC
The mangOH Yellow supports four CF3 module ADC (Analog to Digital converter) signal sources (ADC0-ADC3).
The ADC signals connect to the following sources, as shown in
•
ADC0—IoT Connector 0 (CN1000, slot IOT0), pin 20
•
ADC1—Battery Voltage Monitor (BAT_VOL_MONITOR)
•
ADC2—Expansion connector (CN805), pin 9
•
ADC3—IoT Connector 0 (CN1000, slot IOT0), pin 37 (Hardware modification required)
Figure 2-7: ADC Configuration
2.4.2 Audio (Analog and PCM)
The mangOH Yellow supports the CF3 module PCM (digital) audio signals. The signals connect via a Mux (analog
switch) to the following sources, as shown in
:
•
3.5 mm analog audio jack (Default configuration)
•
IoT connector (Alternate configuration)
ADC2_3.3V
CF3
ADC1
ADC2
ADC0
ADC3
BAT_VOL_MONITOR
ADC2_1V8
Battery Voltage Monitor
(U1003)
Level
Shifter
IoT Connector
(CN601)
ADC3 (Pin 37)
Expansion Connector
(CN805)
Pin 8
ADC0 (Pin 20)
(R608)
Note: Default configuration — Solid lines